SPECIAL COMMITTEE MEETING REPORT 5 JUNE 2019
56. Prior to the commencement of use of the Visitor accommodation Type 4 dwelling units an
acoustic barrier along the common boundary of the development site with the Peregian
Beach Hotel must be constructed. The barrier shall be constructed of materials to achieve a
minimum surface density 12.5 kg/m2 and a height 2.5 metres above the hotel pavement level
along the boundary of the site and adjacent to the hotel drive-through lane and carparking
areas, as shown on Figure 4 and described in Section 4.8 of the Second Joint Report of
Experts in Noise (30 May 2018) for Planning and Environment Court Appeal 4066 of 2017.
57. Written certification is required from a suitably qualified person confirming that sound
pressure levels from all mechanical plant and equipment within the development site comply
with the following when measured at the façade of any habitable room or formal outdoor area
of the Visitor accommodation Type 4 motel building or the Visitor accommodation Type 4
dwelling units. Noise levels to be measured as LAeq adj 15min where adjustments refer to
tonality or impulsivity, in accordance with the most recent edition of the Queensland Noise
Measurement Manual:
a. Air-conditioning and Refrigeration
i. 7am to 10pm: Maximum level allowable = background + 5dB(A)
ii. 10pm to 7am: Maximum level allowable = background + 3dB(A)
b. Pumps
i. 7am to 7pm: Maximum level allowable = background + 5dB(A)
ii. 7pm to 10pm: Maximum level allowable = background + 3dB(A)
iii. 10pm to 7am: No audible noise.
The certification must be submitted to Council prior to commencement of the use, which
certifies that operational noise from any fixed plant and equipment complies with the
requirements of this Decision Notice.
58. Written certification is required from a suitably qualified person confirming that sound
pressure levels from all mechanical plant and equipment from the existing IGA shopping
centre comply with the following when measured at the boundary of the newly created lot.
Noise levels to be measured as LAeq adj 15min where adjustments refer to tonality or
impulsivity, in accordance with the most recent edition of the Queensland Noise
Measurement Manual:
a. Air-conditioning and Refrigeration
i. 7am to 10pm: Maximum level allowable = background + 5dB(A)
ii. 10pm to 7am: Maximum level allowable = background + 3dB(A)
b. Pumps
i. 7am to 7pm: Maximum level allowable = background + 5dB(A)
ii. 7pm to 10pm: Maximum level allowable = background + 3dB(A)
iii. 10pm to 7am: No audible noise.
The certification must be submitted to Council, which certifies that operational noise from any
fixed plant and equipment complies with the requirements of this Decision Notice. The
certification must be provided prior to sealing of the plan of survey or commencement of use
of the Visitor accommodation Type 4 motel building, whichever occurs first.
59. When requested by Noosa Council, a Noise Impact Assessment Report (NIAR) showing
monitoring and recording of noise levels must be undertaken to investigate any non-
vexatious complaint caused by noise emissions from operations at the premises. Such
monitoring must be undertaken and completed within a reasonable and practicable
timeframe as nominated by council and be performed by a suitably qualified and experienced
person.