Appendix A - Proposal Plans · 51987.44.02
Plans and drawings: the text below has words only, no drawings.
- workmanship and materials shall be in accordance existing building
with relevant current s.a.a codes and statutory existing car
authorities requirements carpark
- all dimensions and levels to be checked on site by spaces
builder before commencing work
- do not scale drawings
5,100
3,000 9,610 7,590 14,610
200 9,410 200 3,700 90 3,280 170 150
A 90 1,600 90 1,590
EMT B
driveway EMT D
2,500
6,127
25 200 2,775 600 2,537 600 2,537 600 2,537 400 3,790 1,600 2,000
400 new piers
200 1,400 400 3,200 400 3,210 390
new piers 89° 59' 31818
cantilevered awning extension. ramp
new decorative dressed EMT A up100mm 1
1530
max grade 1:10
EMT C
1530
200x200hw non-loadbearing posts.
oil finish
new post 3 W1 W2 W3
13236
4 W5 4 11000
25
block door
blockwork as required for D3
2,800 200
200
200
DP
300
870
11
400
new conc floor slab new slab over EXIT D4 W4 bollard
existing sleeper retaining wall
threshold ramp
bunded
28.8sqm
new cafe waste
3,000
awning new 2
7
2,500
ramp
1,200
pass-thru in existing wall.
9
3,860
RL9.90
THOMAS STREET
extension up to Eng. detail EXIT
lot 1a kitchen
3,910
B
100mm
s B
screened
lot 1c
gate
EXIT
bin store
D2 max 14.2sqm
200
grade 1:10 64 sqm total
4,485
800
5,335
RL9.865 new pier new pier
new pier 19.2sqm
200
new pier
10 6 RL10.10 assumed
bollard
200
90 910
FE remove existing shopfronts 1,050
90
RL10.00 assumed K 920 UC UC 1,000 3
90
new blockwork
2,600
1,100
90
1,050
1,050
600
280
new shop 5
ramp up FE s 8
EXIT
post ramp st
D1
90
100mm
up 1:10
90
200
100mm 770
90
770
existing
35mm H RL9.90
lot 1b
2,400
3,025
threshold ramp max
s stair
to AS1428.1-2009 grade 1:10 FE
wc
1,885
wc
1,600
1,885
33.7sqm
180°
1,100 1,200 RL10.00 assumed hb wc hb hb 7 4
9 up ramp 770
14,800
new slab & ramp 100mm
4,485
as required
existing stud wall with steel support columns & UB over duct
100
100
100
LEGEND space?
6
90 existing car
carpark
20555
line marking
replace existing 100x100 hw posts. 200 10,515 90 1,960 1,960 90 1,975
1 place on galv stirrups to eng. detail, D5 spaces
5
post existing shop reduce size of window
col
4,075
opening in existing pavers for new post footing footpath lot 2
as req'd for bin store
200
2
existing kerb line
& potting mix for new climbing vines. pavers
provide stainless steel cabling to posts for climbers existing 200 16,800 200 col
179° 59'
5,800 5,400
15,990
awning 68.4sqm clear new bollard
bunded
door waste
remove existing light framing over
3 and blockwork block existing door
6
200
4,485
screened
bin store
gate
7
20548
cut new opening in existing blockwork
4 to engineer's detail 1 A bollard
cut new opening in existing blockwork
4 to engineer's detail post 7
2
existing roof
200
existing shop
overhang
7,190
5 new wall framing ex 90x45 MGP12 D6 existing
LOSP treated pine studs @ 450 crs lot 3 meters
toilets
new staff amenities to hydraulic detail.
4,485
6 5,400 6,000 5,400
4,190
cut slab for services as required. 99.0sqm clear
provide mechanical ventilation to AS1668.2. 8
new 6.0mm villaboard wall lining to amenities, staff staff
with 100mm rockwool sound batts between studs..
Wetseal floor slab before tiling.
parking parking
200
9
200
new bin stores with powdercoated alum slatted screens. remove existing bin store
7 bunded gully & hose cock to hydraulic detail
post
25
power pole 270° 31814
existing cantilevered awning.
8 new grease trap to hydraulic detail new decorative, non-loadbearing
posts
750 2,585
adjacent carpark
9 existing stud frame. new plasterboard lining 200 13,800 200 3,000
new stud framing as required, inside the line of blockwork RPD
10 to accommodate new threshold ramp & support Lot 1 RP 161212
new timber framed shopfronts.
new plasterboard lining. new ground floor plan 653.7sqm
new kitchen fitout by tenant.
11 any venting of cooking appliances, passing through unit above
to be protected at suspended slab level by suitable fire damper
Kilargo or equivalent, System FL3 -/240/240, to AS1668.1 & AS1530.4 Provision of FIRE EXTINGUISHERS:
0 5 10 To cover Class F fire risks involving cooking oils and fats in kitchens.
To cover Class A fire risks associated with a Class 2, 3 or 5 building or Class 4 part of a building.
dry powder 4.5kg AB-E
no. date amendments FE fire extinguisher (class A fire risks)
wet chemical 2.0litre class K
APPROVED
This plan is certified for compliance with the requirements
A JUNE 2020 AMENDED DOOR SCHEDULE K fire extinguisher (class F fire risks) of the BUILDING ACT 1975, the BUILDING
REGULATION 2006, and attached approval conditions.
Client Location Drawing Drawn Scale 2020 - 2675
F.J. BROWN 1:100@A2
& D.A. LOCK NEW REFER DECISION NOTICE
GROUND FLOOR PLAN AM 1:200@A4
6 THOMAS STREET Project BA
Project NOOSAVILLE Drawing no. Date
QBSA
62 hilton
reg.
terrace
65073
noosaville (07) 5449 9066
[email protected]
PROPOSED
SHOPS 15.0320.1.3A MAR 2020 1.3A