Appendix A - Proposal Plans · 51987.44.02
Plans and drawings: the text below has words only, no drawings.
3,000 9,600 7,600
A
EMT B EMT D
possible vent duct location
from kitchen below 5
89° 59' 31818
new colourbond klip-lok roofing overflow spitter 1000h blockwork
1530
1530
on sarking to manuf specification. through blockwork EMT A EMT C
extend existing box gutter & utilise
existing downpipes 4 sp sp 13236 sp 11000
new open balcony
3,000
awning 28.8sqm
1
extension RWO RWO
l'dry
4,200
B B
bath
colourbond trimdek roofing to
match existing
bed 1 bed 2 bed 3
THOMAS STREET
3° pitch.
11,600
verify on site
179° 59'
4
180°
8,600
balc
7,400
covered
existing unit
20548
20555
replace existing trimdek roofing
as required
living dining balcony escape
2 box gutter stair
existing
kit
awning
LEGEND
1
remove existing roof-sail membrane & 3
form new suspended conc slab to engineer's detail.
selected P4 floor tiling over waterproof membrane. A
fall to rainwater outlets
removal of existing asbestos cement
2 awning soffit to be undertaken by licenced contractors. 3° pitch.
7,390
verify on site
replace rotted timber as required and inspect structural 6,225
3 elements for soundness. structural engineer to inspect if necessary.
new 7.5mm Hardigroove soffit lining on 35x45 battens @450crs
removal of existing asbestos cement awning facade by
4 licenced contractors.
replace with 4.5mm hardiflex to manuf specifications.
FC sheet to be painted black.
Concept Click new spotted gum vertical slats, 42x42 @ 85mm. crs
on proprietry tracks at 450crs max, to manuf. specification. 270° 31814
4
new kitchen below.
5 any venting of cooking appliances, passing through unit
to be protected at suspended slab level by suitable fire damper
Kilargo or equivalent, System FL3 -/240/240, to AS1668.1 & AS1530.4
new first floor plan - workmanship and materials shall be in accordance
with relevant current s.a.a codes and statutory
authorities requirements
- all dimensions and levels to be checked on site by
builder before commencing work
0 5 10 - do not scale drawings
no. date amendments APPROVED
This plan is certified for compliance with the requirements
of the BUILDING ACT 1975, the BUILDING
A JUNE 2020 AMENDED DOOR SCHEDULE REGULATION 2006, and attached approval conditions.
2020 - 2675
Client Location Drawing Drawn Scale
F.J. BROWN 1:100@A2
REFER DECISION NOTICE
& D.A. LOCK NEW
FIRST FLOOR PLAN AM 1:200@A4
Project BA
6 THOMAS STREET
Project NOOSAVILLE Drawing no. Date
62 hilton terrace
noosaville (07) 5449 9066
[email protected]
QBSA reg. 65073 PROPOSED
SHOPS 15.0320.1.4A MAR 2020 1.4A