Appendix A - Proposal Plans · 51987.44.02
Plans and drawings: the text below has words only, no drawings.
- workmanship and materials shall be in accordance
with relevant current s.a.a codes and statutory
authorities requirements
- all dimensions and levels to be checked on site by
builder before commencing work
- do not scale drawings
EMT B EMT D
89° 59' 31818
direct rainwater outlets in slab over EMT A
1530
EMT C
1530
to downpipe.
13236 11000
DP
finished ceiling 2700h 4 EXIT
RL12.7 assumed 5 S.D.
EXIT
rwo rwo
S.D.
finished ceiling 2700h
EXIT
RL12.8 assumed
3 3000 existing S.D.
slab soffit height
EXIT
3100 existing slab soffit height
180°
S.D.
20555
LEGEND
1
remove existing asbestos soffit lining from awning.
work to be performed by suiably licensed personel.
1
check for timber rot & replace as required.
inspect cantilevered supports for awing & structural engineers
179° 59'
to comment as required.
new 7.5mm Hardigroove fibrecement lining to awning soffit,
2 on 35x42 pine battens @ 450crs. 2
paint finish
20548
6.0mm flush jointed Villaboard fibrecement ceiling lining,
3 suspended from existing suspension 'eyes' set into existing soffit.
Use Rondo cross rails and furring channels @ 450max crs
to Rondo specifications.
Denoted thus:
plumbing penetrations to existing suspended slab
4 to be protected with retrofit fire collars;
'Promat Promoseal FCS100' or equivalent to
manuf specifications. -/240/240
new kitchen fitout by tenant.
5 any venting of cooking appliances, passing through unit above
to be protected at suspended slab level by suitable fire damper
Kilargo or equivalent, System FL3 -/240/240, to AS1668.1 & AS1530.4
270° 31814
EXIT EXIT sign to AS/NZS 2293.1
on, above, or adjacent to door at locations shown,
discharging to road or open space
S.D.
interconnected smoke detector complying with AS1670.1
& wired to mains source, activating a
Building Occupant Warning System to AS1670.1
reflected ceiling plan
0 5 10
no. date amendments
APPROVED
This plan is certified for compliance with the requirements
A JUNE 2020 AMENDED DOOR SCHEDULE of the BUILDING ACT 1975, the BUILDING
REGULATION 2006, and attached approval conditions.
Client Location Drawing Drawn Scale 2020 - 2675
F.J. BROWN REFLECTED CEILING 1:100@A2
REFER DECISION NOTICE
& D.A. LOCK PLAN AM 1:200@A4 Project BA
6 THOMAS STREET
Project NOOSAVILLE Drawing no. Date
QBSA
62 hilton
reg.
terrace
65073
noosaville (07) 5449 9066
[email protected]
PROPOSED
SHOPS 15.0319.1.5A MAR 2019 1.5A