Original source · versioned page text
B - Code Compliance.pdf
Water Quality and Drainage Code
Editor’s note— PSP6 Engineering Design Standards - Roads, drainage
and earthworks provides guidance on requirements for preparing an
Erosion Management Plan.
AO14.2
Construction works are designed and managed to restrict
the extent of clearing and soil exposure to the minimum
necessary for access, and safe construction at any one
time.
AO14.3
For buildings:
a) upstream runoff is diverted around the construction
site;
b) sediment barriers are provided downslope of
disturbed areas to prevent sediment washing into
gutters, drains and waterways , wetlands or drainage
lines either on or off the site; and
c) temporary or permanent downpipes are connected to
the stormwater system before laying the roof; or
d) localised erosion is avoided by directing flow from
downpipes over non-erosive areas.
AO14.4
Chemical flocculants used as part of an erosion and
sediment control plan do not harm the environmental
values within receiving waters.
AO14.5
Appropriately sized litter containment areas, with
provision for sorting recyclables are provided for the type
of litter expected to be generated onsite.
Wastewater management and effluent disposal
PO15 AO15 AO16 – Complies
Development does not discharge wastewater unless Wastewater (non-sewage) generated from the All wastewater is discharged into the existing network
it can be demonstrated to not compromise development is collected and contained on-site, and is: comprising reticulated sewer and a rising main on
environmental values of waters and water quality a) lawfully disposed to sewer; or Noosa Drive.
objectives. b) transferred off-site for treatment/disposal to an
appropriately licenced facility;