Council archive · source document
RFI - Attachment-1-Updated_Proposal_Plan · MCU19/0055
Plans and drawings: the text below has words only, no drawings.
Original PDF page 5, section 1. The text section number identifies this passage in the reader.
UNIT B - F.F. AREAS
First Floor Residence (Exc. Voids) : 52.6m² First Floor Residence (Exc. Voids) : 46.3m²
Balcony : 8.2m² Balcony : 12.1m²
First Floor Total : 60.8m² First Floor Total : 58.4m²
T H
Overall Total : 157.3m² Overall Total : 159.6m² NOR
GENERAL NOTES
The builder is responsible to check all
existing services prior to beginning any
construction.
# Denotes cavity slider to manufactuers
specification, frames containing cavity sliders
to be 90mm minimum U.N.O
Builder to verify all dimensions prior to
beginning construction work.
Face fixed glass balustrade Face fixed glass balustrade
Electric HWS to minimum energy efficiency
regulations.
Void Over
2436 stk Roof
Toilets: minimum 4-star dual flush, as rated
2418 sd
Balcony Face fixed glass balustrade
under the Water Efficiency and Labeling
Feature Screen Over Standards scheme (WELS).
Bed 1 r
4.3m x 3.7m oid Ove
Roof V
Tapware: minimum 3-star WELS rated for
Ra
kitchen sinks, basins and laundry troughs.
Balcony
k
2406 lvr
2406 lvr 2406 lvr
ed
Feature Screen Over
4/2406 lvr Showerheads: minimum 3-star WELS rated
showerheads.
robe
2406 lvr
1206 shutter 2427 stk
Vo
SD
Smoke alarms complying with AS 3786
id
FRL 60/60/60
ov
ng
to be installed and connected to consumer
er
livi
820
Glass Balustrade
liv i
0606 lvr
mains power in accordance with NCC part
er
Ens Bed 1
ng
ov
3.7.2
robe
id
2406 lvr
2700 Ceiling
Vo
3/1206 shutter 2400 Joinery All electrical appliances and plumbing symbols
3.3m x 3.5m 1506 lvr are diagrammatical. Refer to builders
Ra
Glass Balustrade 3/1206 shutter
ke
specification for details all fixtures.
820
d
3/ 2103 fg
Void
820
820
Seal wet areas in accordance with N.C.C. Vol. 2.
Bed 2 1206 shutter
Part 3.8.1. Slope floor surface towards fw
DN 3.4m x 3.1m
4/1506 lvr
robe (floor wastes)
DN
Provide lighting in accordance with N.C.C. Vol. 2.
Ens Bed 2
0606 lvr
770 cs
Ens Part 3.8.4.2 & 3
770
Ens 3.2m x 3.3m Provide ventilation in accordance with N.C.C.
Vol. 2. Part 3.8.5
robe Mechanical ventilation in accordance with N.C.C
Vol. 2. and AS1668.2
Dimensions Note:
0606 lvr 1806 lvr 0606 lvr
0604 lvr
All wall dimensions are taken from
Roof Below Roof Below the outside faces of the stud wall.
3/ 2103 fg Roof Below (i.e. selected cladding over omitted for
clarity excluding brick veneer walls).
Climate Code Requirements
Energy efficiency assessor to confirm
adequacy of proposed construction.
PROPOSED FIRST FLOOR PLAN Provide insulation to N.C.C. code requirements
or to BERS certification requirements.
C COPYRIGHT The Drawing and the design depicted on this sheet remains the property of Icon Building design. Reproduction in part or whole is prohibited unless written permission is obtained from Icon Building Design. Plans are design for use on the job address specified in the titleblock only.
Revision Schedule Client Name: Andy & Pamela Pannifex
Sheet Number:05 Project Number:18-076
Revision Number Revision Description Revision Date Issued by Project Address: No. 27 Hill Street, Sunshine Beach
2 PCD 3 28/02/2019 AOW
Climate Zone: 2
3
4
Concept Set 1.1
Development Application
03/03/2019
03/05/2019
BJH
BJH Wind Category: To engineers spec.
First Floor
Email: [email protected] 1.0
Website: www.iconbuildingdesign.com.au Project Issue Date: 30/06/2019 Project Status: Development Application 1.0 Scale: 1 : 100
5 RFI 1.0 30/06/2019 BJH
Phone: 0488209840 Checked/Signed By Director: Bradley Hunt Drawn By: BJH QBCC LIC# 126221
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
RFI - Attachment-1-Updated_Proposal_Plan.pdfRelated documentApplication case desk ↗
About this file
- File size
- 7.9 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.