Council archive · source document
RFI - Attachment-1-Updated_Proposal_Plan · MCU19/0055
Plans and drawings: the text below has words only, no drawings.
Original PDF page 6, section 1. The text section number identifies this passage in the reader.
Frameless glass balustrade with aluminium
Select 67 x 15 P.C. Aluminium
handrail in accordance with NCC regulations
batten screen @ 100mm crs to
fixed to manufacturers specification.
manufacturers detail.
Min. 1000mm high.
600 600 Rendered foamboard cladding fixed to
Colorbond Custom orb roof sheeting 600 manufacturers specification.
fixed to manufacturers specification
for required wind category. (5° pitch).
Aluminum framed windows
to manufacturers specification. Feature beam to engineers detail with
selected EPS sunhood/feature fixed to
beam to manufacturers specification.
Aluminum framed Doors
to manufacturers specification.
Ceiling Height
Frameless glass balustrade with aluminium
2700
Joinery
2400
handrail in accordance with NCC regulations
fixed to manufacturers specification.
Min. 1000mm high.
200 series blockwork wall to
engineers detail. Lined with Axon
Cladding.
Ceiling Height
2700
Rendered brick veneer
Joinery
2400
walls to engineers details.
Select Fence fixed to
manufacturers detail.
1.8m max height NORTH ELEVATION
600 600 600 600 600
Colorbond Custom orb roof sheeting
fixed to manufacturers specification
for required wind category. (5° pitch).
Rendered foamboard cladding fixed to 200 series blockwork wall to
manufacturers specification. engineers detail.
Select 67 x 15 P.C. Aluminium
batten screen @ 100mm crs to
Ceiling Height
manufacturers detail.
2700
Joinery
2400
Select P.C. Aluminium batten
screen and post to manufacturers
and engineering detail.
Rendered brick veneer
walls to engineers details.
Ceiling Height
2700
Joinery
2400
EAST ELEVATION
C COPYRIGHT The Drawing and the design depicted on this sheet remains the property of Icon Building design. Reproduction in part or whole is prohibited unless written permission is obtained from Icon Building Design. Plans are design for use on the job address specified in the titleblock only.
Revision Schedule Client Name: Andy & Pamela Pannifex
Sheet Number:06 Project Number:18-076
Revision Number Revision Description Revision Date Issued by Project Address: No. 27 Hill Street, Sunshine Beach
2 PCD 3 28/02/2019 AOW
Climate Zone: 2
3
4
Concept Set 1.1
Development Application
03/03/2019
03/05/2019
BJH
BJH Wind Category: To engineers spec.
Elevations
Email: [email protected] 1.0
Website: www.iconbuildingdesign.com.au Project Issue Date: 30/06/2019 Project Status: Development Application 1.0 Scale: 1 : 100
5 RFI 1.0 30/06/2019 BJH
Phone: 0488209840 Checked/Signed By Director: Bradley Hunt Drawn By: BJH QBCC LIC# 126221
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
RFI - Attachment-1-Updated_Proposal_Plan.pdfRelated documentApplication case desk ↗
About this file
- File size
- 7.9 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.