Original source · versioned page text
220239 - 44 Williams Road, KIN KIN - SSE - TE222036 - 44 Williams Road, Kin Kin QLD 4571 (1) (1)
Attached to the e-mail MCU22/0168 - Information Response - 44 Williams Road Kin Kin.
Advanced Enviro-septic Design Calculator V9.0 ©
AES The World Leader in Passive Solutions ©
Site Address 44 Williams Rd, Kin Kin 3SP127443] TOTAL2 BEDS State QLD Post Code 4571
Client Name Date of Site Visit
Designers Designers Ph Designer Lic
Chris Taylor, Director, Taylor Environmental 0400 301 364 15055672
Name Number (e.gQBCC)
Plumber Ph Plumb / Drainer
Lic Plumber TBA TBA TBA
Number Lic Number
Designers AES
Council Area Noosa Reginal 11 Date 13/6/2022
Cert Number
This Calculator is a guide only, receiving soil classification, surface water, water tables and all other site constraints addressed by the qualified designer.
System Designers site and soil calculation data entry IMPORTANT NOTES
Enter AES L/m loading rate, "30" for ADV Secondary or "38" Secondary 30 >> This design is for an ADVANCED SECONDARY system
Is this a new installation Y or N Y >> Minimun single vent size is 80mm or 2 x 50mm house vents
Number of Bedrooms 3 >> This is not used in ANY Calculation. If not known use N/A or 0.
Number of persons 5 >> A septic tank outlet filter is NOT RECOMMENDED
Daily Design Flow Allowance Litre/Person/Day 120
Number of rows required to suit site constraints 2 >> The maximum length of a single AES pipe run is 30m or 10 PIPES
Infiltration Soil Category from site/soil evaluation. CATEGORY 4 >> Catagory may require design considerations. Ref AS1547
Design Loading Rate based on site & soil evaluation DLR (mm/day) 10 >> Soil conditioning may be necessary. Ref AS1547 & Comments.
Bore log depth below system Basal area 1.5m >> Min depth 1.5m. Check water table/restrictive layer
Is this design a GRAVITY system with no outlet filter? Y or N Y >> GRAVITY. A House Vent & LOW VENT required on this system
PLEASE CHECK YOU HAVE FALL FROM TANK TO AES SYSTEM PIPES 60
COMMENTS :- " The outcome must be important to everyone. "
- Ripping of receiving surface required in clay soil structures in Cat 4,5,6. In addition refer to AS 1547. Always excavate & rip parallel to the site slope/AES pipe.
- Specialist soils advice & special design techniques will be required for clay dominated soil having dispersive or shrink/swell behaviour. Refer AS1547
- Designers need to be familar with special requirements of Local Authorities. ie - Minimum falls from Septic tank outlets to Land application areas etc
- Plumbers are reminded good construction techniques as per AS1547 are especilly important in these soil types. Refer AS1547 & AES installation Instructions
AES System Calculator Outcomes AES dimensions
AES System Extension Area
Total System load - litres / day (Q). 600 l/d
10.00 Min Length of AES pipe rows to treat loading 10.25 lm Length:(L) 12.60m 31.84m
Number of FULL AES Pipe lengths per row 4 lths Width:(W) 1.35m 3.41m
Sand
Total Capacity of AES System pipe in Litres 1696 ltr. 0.75m 0.15m
Depth :
AES Additional infiltration extension required 43.0 m2 Area m2 17.0 m^2 43.0 m^2
USE CUT LENGTHS OF PIPE IN THIS DESIGN? (ENTER Y) >>Slope percentage must be 0% & infiltration footprint must be level for this design
IF YOU WISH TO USE A TRENCH EXTENSION DESIGN OPTION ENTER "Y" Y Enter Custom Width in metre 4.65
AES INFILTRATION FOOT PRINT AREA - L = Q / ( DLR x W) Length Width Minimum AES foot print required
The length & width of excavation required for this design is >> 12.90m x 4.65m = 60.0 m2 total
AES pipes are best centered in the trench parallel to the site slope
Code AES System Bill of Materials. Chankar Environmental Use Only
AES-PIPE AES 3 metre Lengths required 8 lths
AESC AES Couplings required 4 ea 24.9
AESO AES Offset adaptors 8 ea
AESODV AES Oxygen demand vent 2 ea “Nature's Wastewater Solutions”
AES-IPB AES 100mm Inspection point base 4 ea
TD Kit 4 4 Hole Distribution Box Kit 1 ea
TD Kit 7 7 Hole Distribution Box Kit ea Digitally signed by Steve Dennis
VS43-4 Sweet Air Filter VS43-4 ea DN: cn=Steve Dennis, o=Chankar
AES DESO Double Offset Adaptors ea
Enviromental, ou=Design
Review, email=steve@enviro-
TOTAL SYSTEM SAND REQUIRED (Estimate Only) 28 m3
septic.com.au, c=US
Please email your AES Calculator (EXCEL FORMAT), Site Layout & AES Design to Date: 2022.06.14 15:23:17 +10'00'
[email protected] [email protected]
> The AES Calculator is a design aid to allow checking of the AES components, configuration and is a guide only. Site and soil conditions referencing AS1547 are
calculated and designed by a Qualified Wastewater Designer.
> Chankar Environmental accepts no responsibility for the soil evaluation, loading calculations or DLR entered by the designer for this calculator.
> AES pipes can be cut to length on site. They are supplied in 3 meter lengths only.
> AES ONLY supply AES components as detailed in the Bill of Materials.
> SEPTIC Tank & other components including SAND will need to be sourced from other suppliers. Refer to our WEBSITE www.enviro-septic.com.au OR 07 5474 4055
AES-Design-V9.0-Calculator © Copy Right - Chankar Environmental Pty Ltd 20/1/2022