220239 - 44 Williams Road, KIN KIN - SSE - TE222036 - 44 Williams Road, Kin Kin QLD 4571 (1) (1)

Attached to the e-mail MCU22/0168 - Information Response - 44 Williams Road Kin Kin.

of 19
                                                                  Advanced Enviro-septic Design Calculator V9.0 ©
                                        AES The World Leader in Passive Solutions ©
Site Address 44 Williams Rd, Kin Kin [3SP127443] - SECOND DWELLING TOTAL 2 BEDS                                  State        QLD              Post Code                         4571

Client Name COTTERILL                                                                                                                       Date of Site Visit

  Designers                                                                          Designers Ph                                            Designer Lic
                Chris Taylor, Director, Taylor Environmental                                                   0400 301 364                                          15055672
   Name                                                                                Number                                                 (e.gQBCC)
                                                                                     Plumber Ph                                             Plumb / Drainer
Lic Plumber TBA                                                                                                       TBA                                               TBA
                                                                                       Number                                                Lic Number
                                                                                    Designers AES
Council Area Noosa Reginal                                                                                               11                       Date               13/6/2022
                                                                                     Cert Number
            This Calculator is a guide only, receiving soil classification, surface water, water tables and all other site constraints addressed by the qualified designer.

                        System Designers site and soil calculation data entry                                                     IMPORTANT NOTES

Enter AES L/m loading rate, "30" for ADV Secondary or "38" Secondary                        30          >> This design is for an ADVANCED SECONDARY system
                                           Is this a new installation     Y or N            Y           >> Minimun single vent size is 80mm or 2 x 50mm house vents

                                                          Number of Bedrooms                 2          >> This is not used in ANY Calculation. If not known use N/A or 0.

                                                            Number of persons                3          >> A septic tank outlet filter is NOT RECOMMENDED

                              Daily Design Flow Allowance Litre/Person/Day                  120

                                 Number of rows required to suit site constraints            2          >> The maximum length of a single AES pipe run is 30m or 10 PIPES

              Infiltration Soil Category from site/soil evaluation. CATEGORY                 5          >> Catagory may require design considerations. Ref AS1547

      Design Loading Rate based on site & soil evaluation DLR (mm/day)                      10          >> Soil conditioning may be necessary. Ref AS1547 & Comments.

                                         Bore log depth below system Basal area            1.5m         >> Min depth 1.5m. Check water table/restrictive layer

           Is this design a GRAVITY system with no outlet filter? Y or N                    Y           >> GRAVITY. A House Vent & LOW VENT required on this system
PLEASE CHECK YOU HAVE FALL FROM TANK TO AES SYSTEM PIPES                                           36

COMMENTS :- " The outcome must be important to everyone. "
- Ripping of receiving surface required in clay soil structures in Cat 4,5,6. In addition refer to AS 1547. Always excavate & rip parallel to the site slope/AES pipe.
- Specialist soils advice & special design techniques will be required for clay dominated soil having dispersive or shrink/swell behaviour. Refer AS1547
- Designers need to be familar with special requirements of Local Authorities. ie - Minimum falls from Septic tank outlets to Land application areas etc
- Plumbers are reminded good construction techniques as per AS1547 are especilly important in these soil types. Refer AS1547 & AES installation Instructions

                                AES System Calculator Outcomes                                                                                 AES dimensions
                                                                                                                                            AES System             Extension Area
                                           Total System load - litres / day (Q).            360         l/d

    6.00                        Min Length of AES pipe rows to treat loading               6.25         lm                    Length:(L)         6.60m                20.07m

                                    Number of FULL AES Pipe lengths per row                  2          lths                  Width:(W)          1.35m                 4.10m
                                                                                                                                Sand
                                 Total Capacity of AES System pipe in Litres                848         ltr.                                     0.75m                 0.15m
                                                                                                                               Depth :
                         AES Additional infiltration extension required                    27.1         m2                     Area m2          8.9 m^2               27.1 m^2

                USE CUT LENGTHS OF PIPE IN THIS DESIGN? (ENTER Y)                                        >>Slope percentage must be 0% & infiltration footprint must be level for this design

                 IF YOU WISH TO USE A TRENCH EXTENSION DESIGN OPTION ENTER "Y"                                    Y           Enter Custom Width in metre               5.22

    AES INFILTRATION FOOT PRINT AREA -                   L = Q / ( DLR x W)            Length                   Width                Minimum AES foot print required



  The length & width of excavation required for this design is >>                          6.90m         x      5.22m            =                36.0           m2 total

                    AES pipes are best centered in the trench parallel to the site slope
    Code                          AES System Bill of Materials.                                                                         Chankar Environmental Use Only
AES-PIPE                       AES 3 metre Lengths required                                 4           lths

AESC                               AES Couplings required                                   0           ea                                                                        12.9

AESO                                 AES Offset adaptors                                    8           ea

AESODV                            AES Oxygen demand vent                                    2           ea                                 “Nature's Wastewater Solutions”
AES-IPB                      AES 100mm Inspection point base                                4           ea

TD Kit 4                         4 Hole Distribution Box Kit                                1           ea

TD Kit 7                         7 Hole Distribution Box Kit                                            ea                    Digitally signed by Steve Dennis
VS43-4                             Sweet Air Filter VS43-4                                              ea                    DN: cn=Steve Dennis, o=Chankar
AES DESO                           Double Offset Adaptors                                               ea
                                                                                                                              Enviromental, ou=Design
                                                                                                                              Review, email=steve@enviro-
                TOTAL SYSTEM SAND REQUIRED (Estimate Only)                                  16          m3
                                                                                                                              septic.com.au, c=US
    Please email your AES Calculator (EXCEL FORMAT), Site Layout & AES Design to                                              Date: 2022.06.14 15:22:56 +10'00'
                               [email protected]                                                                      [email protected]
> The AES Calculator is a design aid to allow checking of the AES components, configuration and is a guide only. Site and soil conditions referencing AS1547 are
  calculated and designed by a Qualified Wastewater Designer.
> Chankar Environmental accepts no responsibility for the soil evaluation, loading calculations or DLR entered by the designer for this calculator.
> AES pipes can be cut to length on site. They are supplied in 3 meter lengths only.
> AES ONLY supply AES components as detailed in the Bill of Materials.
> SEPTIC Tank & other components including SAND will need to be sourced from other suppliers. Refer to our WEBSITE www.enviro-septic.com.au OR 07 5474 4055
                                                    AES-Design-V9.0-Calculator © Copy Right - Chankar Environmental Pty Ltd 20/1/2022

Log in to download the original (220239 - 44 Williams Road, KIN KIN - SSE - TE222036 - 44 Williams Road, Kin Kin QLD 4571 (1) (1).pdf)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.