Original source · versioned page text
RFI - Att 1 - Revised Bldg Design Plans
Plans and drawings: the text below has words only, no drawings.
Very large file (11.8 MB): may take a few minutes to open.
Selected Lineaboard (Or similar) cladding Colorbond Custom orb roof sheeting
fixed to manufacturers specification. fixed to manufacturers specification
for required wind category.
5°
380 (W) x 500 (L) Rendered Blockwork Colorbond slotted gutter, fascia
Pier toi engineers detial. to match roofing. Fix to manufacturers
specification.
100 x 50 Aluminium Batten Screen @ 150 Crs.
Max. to manufacturers specification. (ABS)
Ceiling Height
2700
Joinery
2400
Aluminum framed windows
to manufacturers specification.
1° 2°
Aluminum framed Doors
to manufacturers specification.
Ceiling Height
3800 5120 1190
2700
Joinery
2400
1750
1750
Approx. Existing Rendered 200 series blockwork
Ground Line. wall to engineers detail.
Select Feature Stone Cladding fixed 100 x 50 Aluminum Batten Screen @ 150
over 200 series blockwork wall to Crs. to manufacturers specification. (ABS)
manufacturers specification.
Front Fencing - Solid - 4.990m
Transparent Fencing -5.120m Colorbond Custom orb
No fencing Driveway - 4.978m roof sheeting
-------------------------------------------- fixed to manufacturers
Solid Fencing 33% specification
WEST ELEVATION for required wind
Scale : 1 : 100 category.
380 (W) x 500 (L) Rendered Blockwork
Pier toi engineers detial. Colorbond slotted
gutter, fascia
to match roofing. Fix
to manufacturers
specification.
Selected Lineaboard (Or similar) cladding
Approx. Max Build Height From N.G.L @ 2m From Boundary
fixed to manufacturers specification.
Ceiling Height
Aluminum framed windows
2700
Joinery
to manufacturers specification.
2400
6673
Approx. Existing
Ground Line @
Ceiling Height
Line of Fence - Omitted for Clarity
Pool Bdy Wall.
2700
Joinery
2400
SOUTH ELEVATION Approx. Existing
Scale : 1 : 100 Ground Line.
Line Of Pool Behind Line Of Pool Behind
Approx. Proposed
Rendered 200 series blockwork Ground Line.
wall to engineers detail.
Aluminum framed Doors
to manufacturers
specification.
Revision Schedule Project Address : Sheet Name: Project Status: Project Number:
Number Description Date Issued by No. 23 Coral Tree Avenue, Noosa Heads Elevations PCD 17 21-054
3 PCD 15 31/05/22 NZP
4 PCD 16 04/06/22 NZP Client Name : Project Issue Date : Q.B.C.C Lisence No. Sheet Number:
Email: [email protected]
Website: www.iconbuildingdesign.com.au
5 PCD 17 18/08/22 NZP Paddy Guilford 18/08/2022 126221 05
C COPYRIGHT The Drawing and the design depicted on this sheet remains the property of Icon Building design. Reproduction in part or whole is prohibited unless written permission is obtained from Icon Building Design. Plans are design for use on the job address specified in the titleblock only.
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file