Colorbond Custom orb roof sheeting
Selected Lineaboard (Or similar) cladding fixed to manufacturers specification
fixed to manufacturers specification. for required wind category.
5°
Colorbond slotted gutter, fascia
to match roofing. Fix to manufacturers
specification.
100 x 50 Aluminium Batten Screen @ 150 Crs.
Max. to manufacturers specification. (ABS)
Ceiling Height
2700
Joinery
Aluminum framed windows
2400
to manufacturers specification.
2° 1°
Ceiling Height
2700
Joinery
2400
Approx. Existing Line Of Bin
Store Behind
Ground Line. Line Of Floor Behind
Aluminum framed Doors
Rendered 200 series blockwork
to manufacturers specification.
wall to engineers detail.
EAST ELEVATION
Scale : 1 : 100 Line Of Pool Behind
Selected concealed panel lift door Colorbond Custom orb roof sheeting
fixed to manufacturers specification. fixed to manufacturers specification
for required wind category.
Selected Lineaboard (Or similar) cladding Colorbond slotted gutter, fascia
fixed to manufacturers specification. to match roofing. Fix to manufacturers
specification.
Aluminum framed windows
to manufacturers specification.
Ceiling Height
Approx. Max Build Height From N.G.L
2700
Joinery
2400
100 x 50 Aluminium Batten Screen @ 150 Crs.
Max. to manufacturers specification. (ABS)
7592
Select Feature Stone Cladding fixed to
manufacturers specification.
Ceiling Height
2700
Joinery
2400
Rendered 200 series blockwork
wall to engineers detail.
Aluminum framed Doors
Approx. Existing
Ground Line.
NORTH ELEVATION to manufacturers specification.
Scale : 1 : 100
Approx. Proposed
Ground Line.
Revision Schedule Project Address : Sheet Name: Project Status: Project Number:
Number Description Date Issued by No. 23 Coral Tree Avenue, Noosa Heads Elevations PCD 17 21-054
3 PCD 15 31/05/22 NZP
4 PCD 16 04/06/22 NZP Client Name : Project Issue Date : Q.B.C.C Lisence No. Sheet Number:
Email: [email protected]
Website: www.iconbuildingdesign.com.au
5 PCD 17 18/08/22 NZP Paddy Guilford 18/08/2022 126221 06
C COPYRIGHT The Drawing and the design depicted on this sheet remains the property of Icon Building design. Reproduction in part or whole is prohibited unless written permission is obtained from Icon Building Design. Plans are design for use on the job address specified in the titleblock only.
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.