Noise Report

of 23

Page text read automatically using OCR, there may be inaccuracies

Medicentre 2 Pty Ltd ATF Medicentre Properties No 2 Trust
Environmental Noise Level Impact Assessment for Proposed Medical Centre, 45 Maple Street, Cooroy           Page 13 of 20




                    APPENDIX A: AMBIENT NOISE MEASUREMENTS, LOCATION A

Measurement Equipment

The following equipment was used to conduct the ambient noise level study at Monitoring Location A:

   Bruel and Kjaer Type 2250 L Hand Held Analyzer – Serial No. 3003254, with Type BZ 7131, BZ
    7132 and BZ 7133 Software and Prepolarised free-field ½” microphone, Type 4189, Serial No.
    2887684;

   Bruel and Kjaer Type 3592 outdoor microphone kit, including Type UA1404 outdoor microphone;

   Bruel and Kjaer Type AO 0442 ten metre microphone extension cable; and

   Bruel and Kjaer Type 4231 Sound Level Calibrator, Serial No. 3011409.

All of the above equipment is Type 1 in accordance with the requirements of Australian Standard AS
1259-1990, Acoustics – Sound Level Meters, as required by Australian Standard AS 1055.1-1997.


Measurement Equipment Settings

The above equipment was used with the following settings:

   Detector:                         RMS
   Time Weighting:                   FAST
   Frequency Weighting:              A
   Sound Incidence:                  FRONTAL
   Microphone sensitivity:           51.438 mV/Pa


Calibration

The sound level meter was calibrated to the required value of 93.8 dB at 1000 Hz immediately before
and after the noise level measurements were conducted. At no time was an adjustment of more than
0.5 dB required. This complies with the requirements of the Australian Standard.


Monitoring Location

Monitoring Location A was approximately located in the north-west corner of adjoining Lot 103, which
would be representative of the closest part of the future residential lot and most distant from Kawana
Way and the influence of traffic noise. At monitoring location A the microphone was elevated 1.6
metres above ground level. Refer Figure 1 for further details.


Atmospheric Conditions

Throughout the ambient noise level studies, atmospheric conditions generally complied with the
requirements of the Australian Standard. Refer Appendix C for further details. Whilst there was some
rainfall during the monitoring period, this was minimal and as it did not affect the ambient noise levels
there was no need to exclude it from the averaging process.




David Moore & Associates Pty Ltd                                               Our reference: R20018/D3464/Rev.0/9.03.20

Log in to download the original (Noise Report.pdf)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.