The Surf Club Sunshine Beach
Environmental Noise Level Impact Assessment of Proposed Refurbished and Extended
Sunshine Beach Surf Life Saving Club, Duke Street, Sunshine Beach                                         Page 8 of 31




AMBIENT NOISE LEVELS, MONITORING LOCATION A

Table 1 details the range and average ambient noise levels at Monitoring Location A (north of the
Sunshine Beach Surf Life Saving Club at Costa Nova, 1 Belmore Terrace, Sunshine Beach). This
monitoring location was on the south/south-east facing balcony of Unit 5, with direct line of sight to the
Sunshine Beach Surf Life Saving Club, first floor level of Costa Nova, with the microphone elevated 1.6
metres above balcony level. The results of this ambient noise assessment would be representative of
the ambient noise levels at the residential to the north and west of the Sunshine Beach Surf Life Saving
Club.

For details of measurement equipment, equipment settings, monitoring location and atmospheric
conditions for the weekdays and weekend, refer Appendix A, whilst Appendix B details all of the key
parameter results of the ambient noise level measurements.

With respect to noise the following should be noted:

    •    daytime:           0700 to 1800 hours;
    •    evening:           1800 to 2200 hours;
    •    night-time:        2200 to 0700 hours;
    •    ‘A’ weighted:      adjustment made by the sound level meter to the measured noise to
                            correspond to the response of the human ear. This adjustment is
                            standardised by international noise standards;
    •    LAeq,T:            the equivalent continuous (or approximately the ‘average’) ‘A’ weighted sound
                            pressure level for the measurement period ‘T’;
    •    LA1,T:             the ‘A’ weighted sound pressure level exceeded for 1% of the measurement
                            period ‘T’;
    •    LA10,T:            the ‘A’ weighted sound pressure level exceeded for 10% of the measurement
                            period ‘T’, which is an approximation of the ‘average of the maximum noise
                            levels’;
    •    LA90,T:            the ‘A’ weighted sound pressure level exceeded for 90% of the measurement
                            period ‘T’, which is an approximation of the ‘average of the minimum noise
                            levels’, which is also known as the ‘background’ noise level.




David Moore & Associates Pty Ltd                                            Our reference: R17049/D3248/Rev.0/21.07.17
Log in to download the original file

Attachment E - David Moore NOISE REPORT.pdf · 3.3 MB (large file)

Large file: the download may take up to a minute.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.