App 5 - Wastewater Design

of 10

Page text shows just the words. Original shows the document exactly as it was published.

Page text read automatically using OCR, there may be inaccuracies

5/10


[OCR of page images]
ADVANCED

ENVIRO-SEPTIC’ Advanced Enviro-septic Design Calculator V8.6 ©

“Always The First Option”

 

"Always the BEST Option" until site and soil conditions rule it out.

 

 

 

 

 

 

Site
‘Addiess 328 Upper Pinbarren Creek Rd, Pinbarren State Qld Post Code 4568
Client
“tent Viki Dioszegi Date of Site Visit 15/2/19
Name
De s De s Ph ®
<SIENETS 5 water Designs Pty Lid signers 0407 887 321 Number 1049265,
Name Number ™
Phanb. Plumber Ph Plumb / Drainer
umber Number Lic Number
Cc cil Des: rs AES
one" “Noosa Council Stenes AESBR000001 Date 18/2/19
Area, Cert Number

 

 

 

This Calculator is a guide only, receiving soil classification, surface water, water tables and all other site constraints addressed by the qualified designer.

IMPORTANT NOTES

 

 

 

 

 

 

 

 

 

 

 

 

 

fe/meter loading rate, "30" for Advanced Secondary or "38" Secondary 30 [>> This design is for an ADVANCED SECONDARY system
Is this a new installation Y or N Y >> Minimun single vent size is 80mm or 2 x 50mm house vents
Number of person 2 a septic tank outlet filter is NOT RECOMMENDED
Daily Design Flow Allowance Litre/Person/Day 120
Number of rows required to suit site constrants 2 >> The maximum Ith of a single AES pipe run is 30 meters
irface Soil Category as established by site and soil evaluation. CATEGORY 5 >> Catagory may require design considerations. Ref AS 1547
Design Loading Rate based on site & soil evaluation DLR (mm/day) 10 >> Soil conditioning may be necessary. Ref AS1547 & Comments.

Bore log depth below system Basel area 600 >> Min depth below basel area is 600 mm to establish water table or re
Enter System footprint Slope in % for standard AES systems to calculat| 3 >> Consideration required for Sloping sites. Ref AS1547. refer comme!

Is this design a gravity system with no outlet filter?’ Y or N y >> A House Vent & LOW VENT required on this system

 

PLEASE CHECK YOU HAVE FALL FROM TANK TO AES SYSTEM PIPES

 

 

COMMENTS :-" The outcome must be important to everyone. "
- Ripping of receiving surface is required in clay soil structures in Cat 4,5,6. In addition refer to AS 1547. Always excavate and rip parallel to the site slope/AES pij
- Specialist soils advice and special design techniques will be required for clay dominated soil having dispersive or shrink/swell behaviour. Refer AS1547

= Designers need to be familar with special requirements of Local Authorities. IE - Minimun falls from Septic tank outlets to Land application areas. ete

- Plumbers are reminded that good construction techniques as per AS1547 are especilly important in these soil types. Refer AS1547 & AES installation Instructions

 

 

 

 

 

 

Total System load - litres /day (Q). 240 Wid AES System System Extension
Min Length of AES pipe rows to treat loading 4.0 Im Lith m : (L) 6.6 6.6
Number of FULL AES Pipe lengths per row 2 Iths Width m:(W. 1.35 2.29
and 0.75 0.15
Total Capacity of AES System pipe in Litres 848 Itr. Death : .S
Area m2 8.9 15.1

 

IDO YOU WISH TO USE CUT LENGTHS OF PIPE IN THIS DESIGN? (ENTER Y) |

 

 

 

 

 

IF YOU WISH TO USE A TRENCH EXTENSION DESIGN OPTION ENTER "Y" Enter Custom Width in metre
AES INFILTRATION FOOT PRINT AREA - L=Q/(DLRx W) Length Width Minimum AES foot print required .
for this Basic Serial design is 6.6 x 3.64 = 24.0 m2 total

 

 

 

SSSne ese Chankar Environmental Use Only
AES-PIPE AES 3 mtr Lths required 4 Iths Digitally signed by
ARSC ESC Coupl od 2 Steve Dennis
AESC s
‘ouplings requir ca DN: cn=Steve
AESO AESO Offset adaptors 4 ea Dennis,
AESODV AES Oxgen demand vent 1 ca o=Chandar
_ Enviromental,
AES-IPB AES 100mm Inspection point base 2 ca CQERVIRE Se pTc” ou=Resign Review,
i™ "Nature's Wastewater Solutions” '
AES Equ AES Speed Flow Equaliser ca email=designrevie
w@enviro-
AES DESC Double Offset Adaptors ea septic. comany
TOTAL SYSTEM SAND REQUIRED (Guide Only) ut m3 c=AU

 

 

Date: 2019.02.18
13:31:38 +10'00'

[email protected]

PLEASE email your AES CALC and Drawings to

[email protected]

 

 

 

> The AES Calculator is a design aid to allow checking of the AES components and configuration and is a guide only. Site and soil
conditions referencing the AS 1547 standard are calculated and designed by a Quailified Designer
> Chankar Environmental has no responsibility for the soil evaluation, loading calculations or DLR entered by the designer for this calculator

> AES pipes can be cut to lenght on site. They are supplied in 3 meter lths only.

 

 

 

AES -Design-V8.6-Calculator ©__Copy Right - Chankar Environmental pty Itd 14/3/2016

 

 

5/10
Log in to download the original file

App 5 - Wastewater Design.pdf · 1.6 MB (small file)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.