Appendix B - Geotechnical Investigation Report
Across the central portion of the site the site surface levels sloped down to the north at between about
25o and 40o (see Plate 2) to a gently sloping lower portion that extended northwards into neighbouring
bushland. The slope also extended north-west and south-east beyond the site boundaries.
Plate 2: steep slope crossing the central portion of the site (looing south-east)
The steeper (south-eastern) portion of the central sloping area was overgrown and the “rock RW”
indicated on the survey plan was not visible. Upslope of the central sloping area a timber sleeper
retaining wall supported the relative flat yard area to the south. For more details on the retaining walls
see Section 4.3.4 below.
4.3.2 Groundwater and Surface Drainage
As noted in Section 4.2 above, no groundwater was encountered within the depth of the investigation.
Based on the topographic setting of the site, surface run-off from the south not captured by the roads
stormwater drainage system would be directed down to the north and north-east through the site to the
bushland downslope.
Locally, some run-off from the upper section of the site may be captured by drainage behind the retaining
walls within the upper yard area.
4.3.3 Vegetation
The site contained a number of medium to large sized trees which also occupied the neighbouring
properties. The northern portion of the neighbouring property to the east was grass covered.
The bushland to the north extends to the lake foreshore and contained numerous trees (maximum height
about 20m).
Based on our site observations there were occasional trees that were leaning and/or had curved bases
over the steeper section of the central sloping area of the site (see Plate 2 above).
35891URrpt Rev1 4