Attachment 1 – Code Assessments


Performance outcomes                                 Acceptable Outcomes                                  Response

                                                     Habitable buildings are not located within an
                                                     easement for a distribution line.

PO19                                            AO19                                         Not Applicable
Development is located and designed to avoid or Noise emissions do not exceed 5db(A) above Site not located within proximity of major electrical
minimise noise nuisance from the use of background noise level internal to a habitable infrastructure or substations.
infrastructure.                                 building measured in accordance with AS1055.

PO20                                            AO20                                               Not Applicable
Wherever practicable habitable buildings are Where adjoining substations or major electricity Site not located within proximity of major electrical
orientated to avoid direct overlooking of major infrastructure, habitable buildings are orientated infrastructure or substations.
electricity infrastructure or substations.      so that the majority of outdoor living areas and
                                                windows of habitable rooms face away from
                                                the infrastructure.

Earthworks and Drainage                            AO21                                              Complies
PO21                                               Filling other than accessways:                    It is not anticipated that filling at a large scale will
Earthworks and drainage operational works do not                                                     be required to facilitate the proposed dwelling.
                                                         1. does not extend more than the equivalent
directly, indirectly or cumulatively cause adverse                                                   Please refer to the cut and fill plans included at
                                                            of 3 metres around the main building,
impacts external to the development site by:                                                         Attachment 3.
                                                            measured from the outer walls of the
                                                            building;
    1. causing ponding of water on the site or ne
         arby land;                                      2. is limited to a maximum of 500m2; and

    2. increasing flooding, which adversely affect       3. does not impact on the local drainage of
       s the safety or use of any land upstream             adjoining properties.
       and downstream;

Used in these records

About this file

File size
434 KB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Attachment 1 - Code Assessment .pdf · 434 KB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.