Council archive · source document
RFI - Revised Plans · MCU20/0074
Plans and drawings: the text below has words only, no drawings.
ELEC ex
dp A/C HWS dp Z:\14_Nigel's Backup\STUFF\107\LOT 107 WKG
DWG'S Stage 1 Rev D 201004.pln
REVISION A
ABODE SOLUTIONS
Design & Drafting
0400 799 146
820
dp
1 Ground Floor Electrical Plan
dp
1:100
dp
820
dp
dp A/C HWS dp
ELEC ex
ELECTRICAL LEGEND (Per Unit) NOTES
ALL SMOKE ALARMS ARE TO BE
PHOTOELECTRIC TYPE COMPLYING WITH
QTY QTY QTY AS3786 - 2014
NOTES
1 SINGLE GPO POINT 0 DOUBLE PARAFLOOD LIGHT
1 CEILING FAN 3 BLADE PROVIDE ENERGY EFFICIENT LIGHTING TO
80% OF TOTAL FLOOR AREA AS PER
8 DOUBLE GPO POINT 1 IXL LIGHT SUSTAINABLE HOUSING REQUIREMENTS.
ELECTRICAL POWER POINT IN CEILING FOR
u 0 CEILING FAN/LIGHT 3 BLADE The designs and drawings shown on these plans
1 ARIAL BOOSTER IF REQUIRED
0 UNDER BENCH GPO POINT EXTERNAL BUNKER @ 2400 are copyrighted and remain the property of
Abode Solutions, Unauthorized copy/distribution
ELECTRICAL NOTES
u SINGLE BATTEN FLUORESENT of these plans is prohibited.
0 DOUBLE GPO POINT 2 1. ALL MATERIALS AND WORKMANSHIP
LIGHT WITH DIFFUSER 0 CEILING FAN STAINLESS 3 BLADE SHALL BE IN ACCORDANCE WITH AS 3000. Client Name
ex DOUBLE BATTEN FLUORESENT 2. ALL WORK SHALL BE PERFORMED BY Mr M Tarrant
1 EXTERNAL GPO POINT 0 LICENSED ELECTRICAL TECHNICIANS. Project Name
LIGHT WITH DIFFUSER
0 FO FIBRE OPTIC
ex EXTERNAL DOUBLE
3. ALL CONDUITS AND WIRING SHALL BE Proposed New Residence
0 0 BONDI ENTRY LIGHT @ 2400 CONCEALED, SIZES SHALL BE IN ACCORDANCE
GPO POINT Lot 107, Tewantin Road,,
1 A/C A/C UNIT WITH AS 3000
Cooroy, Qld, 4563
4. CONFIRM THE LOCATION OF ALL ITEMS ON
0 PENDANT LIGHT (SEE SPEC.) 0 EXHAUST FAN 1 SITE WITH THE OWNER
HWS HOT WATER SYSTEM
5. LIGHT SWITCHES @ 1070 ABOVE FLOOR Drawing Title:
LOW VOLTAGE
0 0 6. NORMAL GPO @ 300 ABOVE FLOOR.
DOWN LIGHT 2 SMOKE ALARM GAS GAS BOTTLES GROUND FLOOR
7. RANGEHOOD GPO @ 1800 ABOVE FLOOR
9
ENERGY EFFICIENT
0
t 1 METER BOX 8. FRIDGE GPO @ 1600 ABOVE FLOOR. ELECTRICAL PLAN
PHONE/DATA POINT ELEC Scale:
DOWN LIGHT 9. DISHWASHER GPO @ 450 ABOVE FLOOR Date: 05.10.2020
As Shown @ A3 Size
tv AND IN CUPBOARD Status:
OYSTER LIGHT TV JACK CD Checked By: NPH
0 0 10. W/MACHINE GPO @ 1200 ABOVE FLOOR
(Circular Fluro)
Project No: Drawing No.:
11. GARAGE GPO ON CEILING.
6 2 WAY LIGHT SWITCH 3 SINGLE LIGHT SWITCH 12. GPO ABOVE BENCHES @100 ABOVE BENCHES
CDP107 SD12
Plot Date: 6/10/2020
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
RFI - Revised Plans.pdfRelated documentApplication case desk ↗
About this file
- File size
- 2.3 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.