                                                                               - 28 -


    Performance outcomes                                  Acceptable outcomes                                                Response
                                       with fire trails or access easements, which are capable   R6.3
                                       of being navigated by conventional vehicles and which     i. The development does not require the provision of a fire trail
                                       link to through roads.                                       for access by Emergency Services due to the proximity of
                                       Or                                                           the Eco-cabins to the car parking area and emergency
                                       AO6.4 Safe access and egress is available at all times       access area which do not require an urban or Rural fire
                                       to all of the development for emergency vehicles and         appliances to access the area to the north of the proposed
                                       personnel.                                                   Eco-cabins.
                                       Or                                                        R6.4
                                       AO6.5 Where an emergency access point is required,        i. Safe ingress and egress is available for Emergency Services
                                       it complies with the relevant works codes and PSP6           to the dedicated car parking area via the entrance roadway
                                       Engineering Design Standards.                                from Noosa Drive
                                                                                                 R6.5
                                                                                                 i. The detailed Engineering design for the car parking area will
                                                                                                    ensure it complies with PSP6 Engineering Design Standards

Lot design
PO7 Lot design and building siting AO7 Each residential lot:                                     R7
minimises bushfire hazard risk to  1 includes a building envelope, identified on a plan of       i. as the development is part of an existing short stay resort,
people and property.                 subdivision;                                                     the RACV Noosa Resort the proposed development does
                                   2 is of sufficient size and shape to allow for efficient           not require building envelopes.
                                     emergency access to buildings for fire fighting             ii. The location and design of the proposed Eco-cabins does
                                     appliances (e.g. by avoiding battle-axe/hatchet lots             allow for access through and around the Eco-cabins to all
                                     and long narrow lots with long access driveways to               areas within the development footprint by Emergency
                                     buildings);                                                      Services.
                                   3 where more than 2500m², achieves setbacks from              iii. The development is in an area of low bushfire hazard,
                                     hazardous vegetation in line with Bushfire Attack                however, assuming that the vegetation wetlands to the north
                                     Level 29 requirements as per AS3959; and                         can carry a vegetation fire a setback has been achieved
                                   4 is designed so that buildings and structures are                 which would expose the structurers to a maximum radiant
                                     sited in locations of lowest hazard within the lot and           heat flux of 16.5kW/m2 which equates to a Bushfire Attack
                                     elements of the development least susceptible to                 Level of 19.
                                     fire are closest to the fire hazard.                        iv. The development is located in an area of low bushfire
                                                                                                      hazard and as such they will be located in the lowest level of
                                                                                                      bushfire hazard within the local area.
                                  RFA18-048 – 22 - RACV NOOSA RESORT – ECO-CABINS - BUSHFIRE HAZARD ASSESSMENT AND MITIGATION PLAN
ROB FRIEND & ASSOCIATES PTY LTD                                                                                                                       17 JUNE 2022

Used in these records

About this file

File size
7.6 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Attachment 6 - Bushfire Hazard Assessment.pdf · 7.6 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.