15SCT0024Tlett150709
Attached to the e-mail MCU14/0039 - Further response to information request.
4. Access Design The amended application provides an access with a minimum width of 8m which is separated from adjacent accesses by a minimum of 20m. A plan of the proposed access location and driveway from Lake Macdonald Road to the subject site is attached to this letter (15SCT0024-01 Revision C). The proposed access width design is sufficient for an HRV to access the site with an SRV waiting to exit. This is considered reasonable due to the very low movements along the access. The access design is consistent with a Type B2 driveway crossover as noted in IPWEAQ Drawing RS-051. Given the low vehicle volumes and very low potential for conflict, the B2 driveway designation is considered suitable and a divided driveway is not warranted. Provision of a divided driveway is also inconsistent with other driveways to 271 Lake Macdonald Drive. The access driveway is also generally consistent with AS2890.2 as it caters for the turn paths of the largest design vehicles expected to use the driveway at any given time as shown in the attached access plan. The driveway is designed to accommodate a minimum 4m width or wider where required by the swept path of an HRV. Passing bays for smaller vehicles are provided every 100m from the access into the subject site. Lake McDonald Drive at the proposed site access has a posted speed limit of 80kph. In the absence of vehicle speed data, a design speed of 90kph (10kph higher than the posted speed limit) is required for sight distance considerations. The driveway sight distances at the proposed location are greater than 270m and exceed AS2890 and Austroads standards for this design speed (200m and 226m respectively). 5. Summary The proposed access is considered to be generally in accordance with AS2890 series, Austroads standards and Overall Outcome 14.4.2b)ii of Council's Agricultural Uses Code. Should you have any queries in relation to this assessment, call Gary Harris on (07) 5479 2455. Yours faithfully, Reviewed By: Gary Harris Richard Jones Project Consultant Senior Associate Director TTM Consulting Pty Ltd RPEQ: 8943 Att: Access Plan (15SCT0024-01 Revision C) 2
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalSearchable page text hides email addresses. Original files are unchanged and may show email addresses.