DOMESTIC SMOKE ALARMS: NOTES: 11 pacific avenue, sunshine beach 4567 lot 2 on SP185673 1. ALL BEDROOMS AND HALLWAYS ARE TO BE INSTALLED WITH 1. ALL CONSTRUCTION TO BE IN ACCORDANCE WITH THE AUSTRALIAN PHOTO ELECTRIC SMOKE ALARMS IN ACCORDANCE WITH BUILDING FIRE DOMESTIC BUILDING CODE. SAFETY LEGISLATION AMENDMENT REGULATION 2016 2. ALL TIMBER FRAMING TO BE IN ACCORDANCE WITH AS 1684.2 2010 roofing alike existing 2. SMOKE ALARMS MUST BE POSITIONED IN ACCORDANCE WITH AS RESIDENTIAL TIMBER FRAMING MANUAL. timber framing + rendered foamboard over 1670.6 - 1997 FIRE DETECTION, WARNING, CONTROL AND INTERCOM 3. PINE FRAMING TO BE MINIUMUM STRESS GRADE MGP 10/MGP12 0° SYSTEMS. 4.HARDWOOD FRAMING TO BE MINIMUM STRESS GRADE F14 & MINIMUM 20.5 3. DEVICES MUST BE EITHER INTERCONNECTED OR HARD WIRED JOINT GROUP J2. (EXISTING DWELLINGS ONLY) THAT CANNOT BE 5. TIMBER FOR TRUSSES TO BE MINIMUM JOINT GROUP JD4. REMOVED FROM DEVICE 6. TRUSSES TO BE FIXED IN ACCORDANCE WITH MANUF. SPECIFICATIONS ALL OTHER FIXINGS TO BE IN ACCORDANCE WITH AS 1684.2 2010 7.LAMINATED BEAM SIZES BASED ON HYNEBEAM SPAN TABLES WHERE NOTE: SMOKE ALARMS TO BE INSTALLED IN ALL HALLWAYS AND BEDROOMS OTHER BRANDS ARE USED, SIZES TO BE CONFIRMED WITH TO EXISTING RESIDENCE MANUFACTURERS SPECIFICATIONS. 8. ALL DIMENSIONS TAKE PRECEDENCE OVER SCALES 9. BUILDER AND TRADES ARE TO CONFIRM ALL MEASUREMENTS, DETAILS AND SPECIFICATIONS PRIOR TO SETOUT AND ORDERING OF MATERIALS 10. ANY ERRORS ARE TO BE ADDRESSED TO THE DESIGNER AS NO RESPONSIBILITY WILL BE TAKEN AFTER CONSTRUCTION HAS COMMENCED Elevation 2 - a aluminium framed windows and doors 11. ALL TRADES ARE TO CONFORM WITH THE CURRENT AUSTRALIAN STANDARDS RELATING TO HIS OR HER OWN WORK 12. TERMITE PROTECTION TO BE PROVIDED AS PER AS 3660.1.2000 painted roof tiles to match existing 2400 2100 gas hws 350 350 Elevation 1 - a gas hws 2000 (owners to confirm gable alteration with builder) painted fascia to owners choice Elevation 3 - a proposed elevations painted tiled roof to match existing rendered existing brickwork replace roller doors and cut NOTE: INSTALLATION OF ALL EXTERNAL MATERIALS BY BUILDER AS PER MANUFACTURERS SPECIFICATIONS AND CERTIFICATION REQUIREMENTS AS OUTLINED BY NCC Elevation 4 - a arches from existing brickwork PROPOSED: CLIENT:CAROLYN CRESSWELL PH: 0402 365 423 BUILDER: TBC MANDY'S DESIGN & DRAFTING SHEET: 5 of 9 DATE: ISSUE NO: EXTENSION SUSAN LINDEQUE PH: 0413 887 850 PH: 0403 481 474 SCALE: 1:100 3 JULY 2018 G NOTE: THESE DRAWINGS TO BE READ IN CONJUNCTION NOTE: BUILDER TO CONFIRM SITING AND DIMENSIONS BEFORE CONSTRUCTION WITH ENGINEERS DRAWINGS RESPONSIBILITY LIES THERE WITH
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
stage 7.pdfRelated documentApplication case desk ↗
About this file
- File size
- 752 KB (small file)
- File type
No other editions are linked here.