Attached to the e-mail Change to DA - 51901.3990.02.
DOMESTIC SMOKE ALARMS: NOTES: 11 pacific avenue, sunshine beach 4567 lot 2 on SP185673 1. ALL BEDROOMS AND HALLWAYS ARE TO BE INSTALLED WITH 1. ALL CONSTRUCTION TO BE IN ACCORDANCE WITH THE AUSTRALIAN PHOTO ELECTRIC SMOKE ALARMS IN ACCORDANCE WITH BUILDING FIRE DOMESTIC BUILDING CODE. SAFETY LEGISLATION AMENDMENT REGULATION 2016 2. ALL TIMBER FRAMING TO BE IN ACCORDANCE WITH AS 1684.2 2010 2. SMOKE ALARMS MUST BE POSITIONED IN ACCORDANCE WITH AS RESIDENTIAL TIMBER FRAMING MANUAL. 1670.6 - 1997 FIRE DETECTION, WARNING, CONTROL AND INTERCOM 3. PINE FRAMING TO BE MINIUMUM STRESS GRADE MGP 10/MGP12 600 SYSTEMS. 4.HARDWOOD FRAMING TO BE MINIMUM STRESS GRADE F14 & MINIMUM 3. DEVICES MUST BE EITHER INTERCONNECTED OR HARD WIRED JOINT GROUP J2. (EXISTING DWELLINGS ONLY) THAT CANNOT BE 5. TIMBER FOR TRUSSES TO BE MINIMUM JOINT GROUP JD4. REMOVED FROM DEVICE 6. TRUSSES TO BE FIXED IN ACCORDANCE WITH MANUF. SPECIFICATIONS ALL OTHER FIXINGS TO BE IN ACCORDANCE WITH AS 1684.2 2010 existing line of floor NOTE: SMOKE ALARMS TO BE INSTALLED IN ALL HALLWAYS AND BEDROOMS 7.LAMINATED BEAM SIZES BASED ON HYNEBEAM SPAN TABLES WHERE TO EXISTING RESIDENCE OTHER BRANDS ARE USED, SIZES TO BE CONFIRMED WITH MANUFACTURERS SPECIFICATIONS. 8. ALL DIMENSIONS TAKE PRECEDENCE OVER SCALES 9. BUILDER AND TRADES ARE TO CONFIRM ALL MEASUREMENTS, DETAILS kit bath AND SPECIFICATIONS PRIOR TO SETOUT AND ORDERING OF MATERIALS 10. ANY ERRORS ARE TO BE ADDRESSED TO THE DESIGNER AS NO RESPONSIBILITY WILL BE TAKEN AFTER CONSTRUCTION HAS COMMENCED 11. ALL TRADES ARE TO CONFORM WITH THE CURRENT AUSTRALIAN STANDARDS RELATING TO HIS OR HER OWN WORK Section 1 12. TERMITE PROTECTION TO BE PROVIDED AS PER AS 3660.1.2000 trusses as per truss timber framing bracing and tie rafters to extension down as per engineers deisign feature flyover porch manufacturers specifications entry 1mx1m area existing roofing shs post ceiling in line 20.5 with existing existing pergola 0° timber posts 2500 2100 1050 bed 1 bed 2 kit 350 slab and footings as per engineers design decking as per engineers design Section 2 Section 3 rafters as per truss manufacturers specifications l'dry/wc ens 2 master ens Section 4 slab and footings as per engineers design sections NOTE: INSTALLATION OF ALL EXTERNAL MATERIALS BY BUILDER AS PER MANUFACTURERS SPECIFICATIONS AND CERTIFICATION REQUIREMENTS AS OUTLINED BY NCC PROPOSED: CLIENT: CAROLYN CRESSWELL PH: 0402 365 423 BUILDER: TBC MANDY'S DESIGN & DRAFTING SHEET: 6 of 9 DATE: ISSUE NO: EXTENSION SUSAN LINDEQUE PH: 0413 887 850 PH: 0403 481 474 SCALE: 1:100 3 JULY 2018 G NOTE: THESE DRAWINGS TO BE READ IN CONJUNCTION NOTE: BUILDER TO CONFIRM SITING AND DIMENSIONS BEFORE CONSTRUCTION WITH ENGINEERS DRAWINGS RESPONSIBILITY LIES THERE WITH
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
stage 7.pdfRelated documentApplication case desk ↗
About this file
- File size
- 752 KB (small file)
- File type
No other editions are linked here.