Council archive · source document
stage 7 · 51901.3990.02
Attached to the e-mail Change to DA - 51901.3990.02.
NOTES: 11 pacific avenue, sunshine beach 4567 unit 2 lot 2 on SP185673 LEGEND TOTALS TOTALS 1. ALL CONSTRUCTION TO BE IN ACCORDANCE WITH THE AUSTRALIAN DOMESTIC BUILDING CODE. 1 SINGLE GPO 1 SMOKE DETECTORS 3 2. ALL TIMBER FRAMING TO BE IN ACCORDANCE WITH AS 1684.2 2010 W - 1W CHANDELIERS RESIDENTIAL TIMBER FRAMING MANUAL. SINGLE WEATHER PROOF GPO 2 2 3. PINE FRAMING TO BE MINIUMUM STRESS GRADE MGP 10/MGP12 2 2 PENDANT LIGHTS DOUBLE GPO 15 4.HARDWOOD FRAMING TO BE MINIMUM STRESS GRADE F14 & MINIMUM TWIN FLOOD LIGHTS - JOINT GROUP J2. 2 DOUBLE WEATHER PROOFGPO - 5. TIMBER FOR TRUSSES TO BE MINIMUM JOINT GROUP JD4. 2W CENSOR 4 6. TRUSSES TO BE FIXED IN ACCORDANCE WITH MANUF. 1200 LED BLADE LIGHTS 1 SPECIFICATIONS ALL OTHER FIXINGS TO BE IN ACCORDANCE WITH EXTERNAL WALL LIGHTS 3 AS 1684.2 2010 LED DOWNLIGHT 21 CEILING FANS 4 7.LAMINATED BEAM SIZES BASED ON HYNEBEAM SPAN TABLES WHERE SWITCH 13 OTHER BRANDS ARE USED, SIZES TO BE CONFIRMED WITH DUAL SWITCH 3 - MANUFACTURERS SPECIFICATIONS. EXHAUST FAN LIGHT 8. ALL DIMENSIONS TAKE PRECEDENCE OVER SCALES TV 1 FAN LIGHT HEATER - 9. BUILDER AND TRADES ARE TO CONFIRM ALL MEASUREMENTS, DETAILS FOXTEL 1 AND SPECIFICATIONS PRIOR TO SETOUT AND ORDERING OF MATERIALS PHONE 1 10. ANY ERRORS ARE TO BE ADDRESSED TO THE DESIGNER AS NO 3 pslit system DATA 1 RESPONSIBILITY WILL BE TAKEN AFTER CONSTRUCTION HAS COMMENCED 11. ALL TRADES ARE TO CONFORM WITH THE CURRENT AUSTRALIAN dividing fence line concrete slab STANDARDS RELATING TO HIS OR HER OWN WORK ducted ventilation 12. TERMITE PROTECTION TO BE PROVIDED AS PER AS 3660.1.2000 required to ensuite dp W light proposed future DOMESTIC SMOKE ALARMS: pool by pool builder dual dp 1. ALL BEDROOMS AND HALLWAYS ARE TO BE INSTALLED WITH 2 PHOTO ELECTRIC SMOKE ALARMS IN ACCORDANCE WITH BUILDING FIRE deck 2 light SAFETY LEGISLATION AMENDMENT REGULATION 2016 foxtel + tv 2 living split system ac 2. SMOKE ALARMS MUST BE POSITIONED IN ACCORDANCE WITH AS (timber) 1670.6 - 1997 FIRE DETECTION, WARNING, CONTROL AND INTERCOM SYSTEMS. bed 1 3. DEVICES MUST BE EITHER INTERCONNECTED OR HARD WIRED light (timber) (EXISTING DWELLINGS ONLY) THAT CANNOT BE W dp REMOVED FROM DEVICE dual lounge/living 2 dual dws 600 2 dual 2 split system ac 2 2 2 2 bed 2 NOTE: SMOKE ALARMS TO BE INSTALLED IN ALL HALLWAYS AND BEDROOMS 2 b/bar 2 foxtel + tv dual electric roller door 2 split system ac wir 2 TO EXISTING RESIDENCE split ac system 2 2 kit (timber) dual garage unit led strip lighting 800 ens kit 1 LEGEND unit 1 TOTALS 2 dual (timber) fw 1 SINGLE GPO 1 1500 (plasterboard lining to garage W dual 2 2 refs 2 + downlights as specified by owner) 1W 2 SINGLE WEATHER PROOF GPO 1 2 light nbn data + usb robe 2 2 shelves vanity lights 2 (plasterboard lining to garage DOUBLE GPO 21 split system ac 2 2 + downlights as specified by owner) 2 dual over mirror 2 DOUBLE WEATHER PROOFGPO - electric roller door split system ac 2 2 2 2W 2 2 garage unit 2 l'dry wms 800 ens 2 2 1200 LED BLADE LIGHTS 1 bed 2 bath linen 1500 1000 2 2 2 phone + data LED DOWNLIGHT 22 tub ens 2 master (timber) fw 1800 screen 2 glass SWITCH 14 screen glass 900 2 2 2 DUAL SWITCH 6 2 dual 1450 TV 2 W 1600 dp gas hws porch light path lights to be discussed instantaneous gas hws FOXTEL 1 PHONE 1 sound proofing required DATA 2 Electrical Plan to each side of dividing walls SMOKE DETECTORS 3 USB CHARGER POINT 1 PENDANT LIGHTS 4 electrical layout TWIN FLOOD LIGHTS - CENSOR 5 EXTERNAL WALL LIGHTS 2 CEILING FANS 2 EXHAUST FAN LIGHT - FAN LIGHT HEATER 1 NOTE: INSTALLATION OF ALL EXTERNAL MATERIALS BY BUILDER AS PER MANUFACTURERS SPECIFICATIONS AND CERTIFICATION REQUIREMENTS AS OUTLINED BY NCC PROPOSED: CLIENT: CAROLYN CRESSWELL PH: 0402 365 423 BUILDER: TBC MANDY'S DESIGN & DRAFTING SHEET: 7 of 9 DATE: ISSUE NO: EXTENSION SUSAN LINDEQUE PH: 0413 887 850 PH: 0403 481 474 SCALE: 1:100 3 JULY 2018 G NOTE: THESE DRAWINGS TO BE READ IN CONJUNCTION NOTE: BUILDER TO CONFIRM SITING AND DIMENSIONS BEFORE CONSTRUCTION WITH ENGINEERS DRAWINGS RESPONSIBILITY LIES THERE WITH
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
stage 7.pdfRelated documentApplication case desk ↗
About this file
- File size
- 752 KB (small file)
- File type
No other editions are linked here.