24850 EXISTING BUILDING 4500
TP 2.01 vertical support post to be Approx.
90 A removed - refer to engineer 155
4905 90 4880 90 1743 2885 90 1264 2600 1252 90 2109 90 1009 90 1009 90 0
TP 3.00 0
5
Site Boundary Site Boundary
E3
Site Boundary
dp + RWH over dp + RWH over dp
GR
0 wc
3 store Stair
cold & 8
1 GR New polycarbonate roller
cold ambient FW door 950 sill
0 0 Unisex
76 67 storage 1 storage 2 kitchen pwd. wc.
3750x 3950W
3 3 900
0 VB Female Height difference to ensure
3
9 cold store no balustrade required from
1 UP inside FFL. to terrace level.
DOORS DOORS Height difference to ensure
09 09 . . . . no balustrade required from
terrace level to existing
New Roller Door
mezzanine ground levels.
2800x 2000W 990mm Max.
over. 990mm Max.
NOTE:
co-ordinate door cold room New grey tint
opening position fridge polycarbonate
with brewery layout
Garden roller door -
Terrace 950mm H. sill
G
N
I
walkway over Turf / Landscape
D CO² off-form conc. 0
LI retaining wall 2
1
U zone 6 TP 2.00
B TP 2.01 on boundary. 1 E2
portal frame over.
G E4
N
I
portal frame over.
T
S
I Loading DN
portal frame over.
X coffee
portal frame over.
portal frame over.
E Dock
02 B
(External) B
16 Retail
1 0 conc.
59 TP 3.00 Bar steps TP 3.00
11
portal frame over.
DN
Brewery
PROJECT AVENUE
NOTE:
co-ordinate door DN New Polycarbonate roller
opening position NOTE: door
with brewery layout Brewery plant to be 4700x 4370W
designed an installed
to "Sparks Brewers"
specifications. planter New grey tint
0 New Roller Door refer for details of polycarbonate
00 plant & infrastructure. roller door
2 2800x 2000W
990mm Max.
18
sc door Entry MSB. Approx.
0
57 OPEN 2140x 870W Main Switch Board
(paint)
Existing
Gum Tree
-20
9
dp Existing Door 5
6
0 9
dp
14-0
0
2
RY
NA
Height difference to
double 200x50 dressed hwd bollard as
posts & beams to sail support
New Shade Sail
required for pwd.
ensure no balustrade
I
LIM
over to Entry required from terrace
remove existing sliding glass replace existing sliding glass level to existing ground
levels.
E
PR
Wash down doors & insert new doors with New SL.G DR.'s
bunded area polycarbonate roller door. 2140 H. to match existing. PWD. SHARED ZONE
(CHECK!) Black metal lettering / signage
New Polycarbonate roller A
door onto face of conc. wall
2400x 4475W TP 3.00 Garden 4 m² Max area.
1. PWD. Terrace off-form conc. retaining
Loading Area Turf / Landscape wall on boundary.
2.
(4) Scooter Parks
wheelstops to
Sc. 1 Sc. 2 Sc. 3 Sc. 4 Australian Standards
8. 5.
STAFF.
3.
Carpark & Turn Around
9. 6.
NO
wheelstops to RT
Australian Standards STAFF. 4. 200
H
3550
additional new conc. slab to
driveway / carpark to match
Tree to be removed existing - refer to eng.
10. 7.
additional new conc. slab to STAFF.
driveway / carpark to match 13.
existing - refer to eng.
Site Boundary
0m 2m 4m 6m 8m 10m
0
11. 12. 05
0 VISUAL SCALE 1:100 @ A2
0
4
2 STAFF. E1
Existing Trees to
remain. (approx)
TP 2.00
1 PROPOSED
1 : 100
- Ground Floor Plan
Existing Trees to VENTURE DRIVE
remain. (approx)
a: suite 6, 8 kingfisher drive, peregian beach, qld 4573 Boiling Pot Brewery Scale @ a2 As Shown
p: (07) 5471 3033
www. sparksarchitects .com TOWN PLANNING Noosaville Queensland Boiling Pot PTY LTD 140 PROPOSED - Ground Floor Plan TP 1.01
sparks architects pty. ltd. abn 89 124 611 721 project client job no. drawn drawing dwg no.
qld architect's registration No. 3974
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalVery large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.