sewer manhole
timber site details
g line
stormwater manhole S 786
building RP48111
area
l buildin
existing trees to 4 Arakoon Crescent
Sunshine Beach, QLD 4567
erosion prone
be removed
gully trap
coasta
deck Lot 784 on RP 48111
nt
Site Area 570 sqm
I 10° 30 041m
pressure sewer existing tree to be
' 135''
ce
site bo
unitywater records undary removed and replaced
I 7.
I 40.234
res
m appr
ox I 10
undary
0° 30'
135''
nc
existing trees to be
approx
site bo
removed and replaced
k oo
12m
ara
proposed 784
approx I 6° I 8.067m
51' 135''
driveway
provide modified RP48111 proposed multi-storey
crossover to ipwea 604m2
ary
building as part of a
135''
std dwg RSD-100
areas
site bound
different application
0° 30'
locally modify verge
ox I 19
profily to tie into power pole
proposed crossover
m appr
heights by civil thick vegetation 4m
15.088
engineer design
I
existing trees to be
undary
removed and
12m
site bo
replaced
site bo
proposed upgrading undary
I 39.721
m appr
of existing driveway ox I 10
784 0° 30'
135'' existing tree to be
site boundary I 15.5
removed and replaced
RP48111
2.45m existing tree to
be removed
locally modify verge 570m2
profily to tie into
proposed crossover thick vegetation
heights by civil proposed two
70m approx I 356°
engineer design
pressure sewer storey building
135''
unitywater records
2.29m
0° 30'
existing tree to be
removed and replaced
ox I 19
08' 135''
notes
m appr
ar
ak
15.088
oo
1. All works to be carried out in
nc
I
undary
accordance with the general
re
2m
sc
construction notes on coversheet
site bo
en
site bo
of this package.
t
undary
I 35.858
m appr
ox I 28
0° 30'
135''
2. All works to be carried out in
deck
accordance with the DA and BA
including drawings & conditions.
multi storey
building 3. Handrails are required to all
stairsways where a change of
783
level of 575mm or greater occurs
RP48111
as per BCA 2013 Part 32.9.2.4.
1 site plan
- 1 : 300
DRAWN REV DATE ISSUE PROJECT CLIENT DRAWING NAME PHASE DWG NO REV PROJECT NO 0428
aca A 18/04/2024 client review 4-6 Arakoon Crescent BV Investments Pty Ltd southern house SD S100.01 C SCALE As indicated
aca B 11/06/2024 DA issue review Sunshine Beach QLD 4567
A3
site plan
aca C 05/02/2025 council RFI's response
schematic design 1:1 @
Document Set
Do not scale ID:
from 23546502
24063175
drawings. Dimensions are to be checked on site prior to commencement of work. Discrepancies to be brought to the attention of the author. Any dimensions not nominated must be referred to the Architect for confirmation. The concepts and information contained in this document are the copyright of Architect. Use or copying of the document in whole or in part without the written permission of the Architect constitutes an infringement of copyright.
Version: 1, Version Date: 28/08/2025
12/02/2025