Gardens for a reactive site • Water that is transmitted into masonry, metal or timber building
elements causes damage and/or decay to those elements.
• High subfloor humidity and moisture content create an ideal
environment for various pests, including termites and
spiders.
• Where high moisture levels are transmitted to the flooring and
walls, an increase in the dust mite count can ensue within the
living areas. Dust mites, as well as dampness in general, can be
a health hazard to inhabitants, particularly those who are
abnormally susceptible to respiratory ailments.
The garden
The ideal vegetation layout is to have lawn or plants that require only light
watering immediately adjacent to the drainage or paving edge, then more
demanding plants, shrubs and trees spread out in that order.
Overwatering due to misuse of automatic watering systems is a common
cause of saturation and water migration under footings. If it is necessary
to use these systems, it is important to remove garden beds to a
completely safe distance from buildings.
Existing trees
Where a tree is causing a problem of soil drying or there is the existence
or threat of upheaval of footings, if the offending roots are subsidiary
and their removal will not significantly damage the tree, they should be
severed and a concrete or metal barrier placed vertically in the soil to
prevent future root growth in the direction of the building. If it is not
possible to remove the relevant roots without damage to the tree, an
application to remove the tree should be made to the local authority. A
prudent plan is to transplant likely offenders before they become a
problem.
Information on trees, plants and shrubs
State departments overseeing agriculture can give information regarding
root patterns, volume of water needed and safe distance from buildings
of most species. Botanic gardens are also sources of information. For
information on plant roots and drains, see Building Technology File 17.
Excavation
Excavation around footings must be properly engineered. Soil
extend outwards a minimum of 900 mm (more in highly reactive soil) and supporting footings can only be safely excavated at an angle that allows
should have a minimum fall away from the building of 1:60. The finished the soil under the footing to remain stable. This angle is called the angle
paving should be no less than 100 mm below brick vent bases. of repose (or friction) and varies significantly between soil types and
It is prudent to relocate drainage pipes away from this paving, if possible, conditions. Removal of soil within the angle of repose will cause
to avoid complications from future leakage. If this is not practical, subsidence.
earthenware pipes should be replaced by PVC and backfilling should be Remediation
of the same soil type as the surrounding soil and compacted to the same Where erosion has occurred that has washed away soil adjacent to
density. footings, soil of the same classification should be introduced and
Except in areas where freezing of water is an issue, it is wise to remove compacted to the same density. Where footings have been undermined,
taps in the building area and relocate them well away from the building – augmentation or other specialist work may be required. Remediation of
preferably not uphill from it (see BTF 19). footings and foundations is generally the realm of a specialist consultant.
It may be desirable to install a grated drain at the outside edge of the Where isolated footings rise and fall because of swell/shrink effect, the
paving on the uphill side of the building. If subsoil drainage is needed this homeowner may be tempted to alleviate floor bounce by filling the gap
can be installed under the surface drain. that has appeared between the bearer and the pier with blocking. The
danger here is that when the next swell segment of the cycle occurs, the
Condensation extra blocking will push the floor up into an accentuated dome and may
In buildings with a subfloor void such as where bearers and joists support also cause local shear failure in the soil. If it is necessary to use blocking,
flooring, insufficient ventilation creates ideal conditions for it should be by a pair of fine wedges and monitoring should be carried
condensation, particularly where there is little clearance between the floor out fortnightly.
and the ground. Condensation adds to the moisture already present in the This BTF was prepared by John Lewer FAIB, MIAMA, Partner,
subfloor and significantly slows the process of drying out. Installation of Construction Diagnosis.
an adequate subfloor ventilation system, either natural or mechanical, is
desirable.
Warning: Although this Building Technology File deals with cracking in
buildings, it should be said that subfloor moisture can result in the
development of other problems, notably:
The information in this and other issues in the series was derived from various sources and was believed to be correct when published.
The information is advisory. It is provided in good faith and not claimed to be an exhaustive treatment of the relevant subject.
Further professional advice needs to be obtained before taking any action based on the information provided.
Distributed by
CSIRO PUBLISHING Locked Bag 10, Clayton South VIC 3169 Tel (03)
9545 8400 1300 788 000 www.publish.csiro.au Email:
[email protected]
© CSIRO 2003. Unauthorised copying of this Building Technology File is prohibited
8894-193 Sankeys Rd-FEDERAL Page 15 of 15 19/07/2023
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Appendix E - Geotechnical site classification report.pdfRelated documentApplication case desk ↗
About this file
- File size
- 4.6 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.