Appendix H. Planning Scheme Code Responses

Attached to the e-mail Retail Bus Type 5 & Type 2 & Op Works Economic Report & PScheme Code Response - MCU17/0572 & OPW17/0611.

of 69

Page text shows just the words. Original shows the document exactly as it was published.

Page text read automatically using OCR, there may be inaccuracies

                                                                                                                                                           NOOSAVILE LOCALITY CODE
                                                                                                                                           Performance Criteria and Acceptable Solutions



                                                                                                                                                                           COUNCIL USE
             SPECIFIC OUTCOMES                             PROBABLE SOLUTIONS                      SOLUTIONS*                         COMMENTS
                                                                                                                                                                              ONLY
                                                   a)   where slab on ground construction is
                                                        used, filling does not extend more
                                                        than 1m beyond the building footprint,
                                                        measured from the outer walls of the
                                                        building ; or
                                                   b)   the design consists of a suspended
                                                        floor construction.

    Sloping sites & ridgelines                                                                                 Complies with Specific Outcome
    O19                                            S19.1                                                        The site generally slopes from the north to the south at
    Development on sloping sites—                  Buildings and associated accessways are                      a grade of approximately 5%.
    a) is responsive to the natural topography     not constructed on land with a slope
       of the site and minimises cut and fill;     greater than 25% (1 in 4); and
    b) does not visually dominate the hill slope
       or interrupt the skyline;                   S19.2                                              N/A       Not applicable
    c) is integrated with the natural site         Buildings are of split level design that step
       characteristics including vegetation;       down the slope or have suspended floor
       and                                         construction; and
    d) for Multiple housing, takes the form of
       small separate buildings; and
                                                   S19.3                                              N/A       Not applicable
                                                   Cut or fill is less than 1.2m in depth; and

                                                   S19.4                                              N/A       Not applicable
                                                   The distance between the ground and the
                                                   lowest part of the floor of the building does
                                                   not exceed 3m to avoid large under
                                                   building areas; and

                                                   S19.5                                                       Complies with Specific Outcome
                                                   Buildings present no more than 2 or 3                        The proposed development is 1 storey in height, as
                                                   storeys at any one point.                                    shown on the Architectural Plans provided at Appendix
                                                                                                                C.

    O20                                            S20.1                                              N/A       Not applicable
    On steep slopes or ridgelines which are        No solution provided                                         The site is not located on a steep slope or ridgeline.
    visible from the major road network, areas

1       Solution:  = Acceptable Solution                                                                                                                                     Appendix H
                  A/S = Alternative Solution
                  N/A = Not applicable to this proposal

PR137996-1                                                                                                                                                                       Page 9
Log in to download the original file

Appendix H. Planning Scheme Code Responses.pdf · 1.1 MB (small file)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.