Original source · versioned page text
Appendix H. Planning Scheme Code Responses
Attached to the e-mail Retail Bus Type 5 & Type 2 & Op Works Economic Report & PScheme Code Response - MCU17/0572 & OPW17/0611.
BUSINESS USES CODE
Performance Criteria and Acceptable Solutions
Table 14-5 – For all Business Uses
PROBABLE SOLUTIONS COUNCIL USE
SPECIFIC OUTCOMES SOLUTIONS* COMMENTS
(IF CODE ASSESSABLE) ONLY
14.17 Effects of use
Electricity infrastructure Complies with specific outcomes
O1 The development does not adversely S1.1 No solution provided. As demonstrated in the Civil Engineer Report provided
impact on existing or future electricity at Appendix F, existing electrical infrastructure is
supply infrastructure; available to the site along the Eumundi Noosaville Rd
AND frontage. Detailed design will determine the extent of
any upgrades required to the existing infrastructure to
ensure no adverse impacts.
O2 All uses and works maintain an S2.1 Development for uses adjacent to or N/A Not applicable
adequate safe distance from electrical within 50m of an existing electricity The subject site is not within 50m of an existing or future
infrastructure including substations, substation incorporates noise attenuation electricity substation.
overhead powerlines, power poles and measures to mitigate noise impacts; and
transformers. S2.2 Buildings and structures (including Complies with probable solutions
swimming pools, sheds, tennis courts and As shown on the Architectural Proposal Plans provided
outbuildings) are not constructed under at Appendix C, the built form is appropriately setback
overhead electricity transmission lines, or from the property boundaries with adequate separation
within electricity easements. from the existing electrical infrastructure located within
the verge.
14.18 Amenity
O3 Development is designed and sited to S3.1 No solution provided. Complies with specific outcomes
avoid noise emissions that unreasonably
diminish the amenity of the area or The site is zoned for industrial activities and is not
surrounding uses. located within proximity to any sensitive receiver. The
proposed form of development is therefore considered
to be designed and sited appropriately. Please refer to
the aerial image provided as Figure 6 of the submitted
town planning report and Architectural Proposal Plans at
Appendix C, providing context to the surrounding
nature and form of development.
Mechanical plant and equipment and Complies with specific outcome
storage areas
As shown on the Architectural Proposal Plans at
1 Solution: = Acceptable Solution Appendix H
A/S = Alternative Solution
N/A = Not applicable to this proposal
PR137996-1 November 2017 Page 1
See the original