Appendix H. Planning Scheme Code Responses
Attached to the e-mail Retail Bus Type 5 & Type 2 & Op Works Economic Report & PScheme Code Response - MCU17/0572 & OPW17/0611.
BUSINESS USES CODE
Performance Criteria and Acceptable Solutions
PROBABLE SOLUTIONS COUNCIL USE
SPECIFIC OUTCOMES SOLUTIONS* COMMENTS
(IF CODE ASSESSABLE) ONLY
O4 Mechanical plant and equipment S4.1 Mechanical plant and equipment Appendix C, no mechanical plant equipment is located
(including air conditioning equipment) and are— within 2m of the property boundary. Furthermore,
storage areas are designed and located (a) located more than 2m from any appropriate screening is provided to the service yard
to— property boundary; ensuring any plant equipment is not visually intrusive.
(a) avoid adverse visual impacts when (b) where located at ground level,
viewed from the street and adjoining screened by fencing 1.5m in height or
properties; and dense vegetation of at least 1.5m in
(b) visually integrated with the building width incorporating grouped trees and
design. shrubs with maximum separation
distance of 1m measured from the
centre of the tree or scrub; and
(c) are visually integrated into the line and
plane of the building and roof design
and do not project beyond the height
or width of the building when viewed
from the street and adjoining
properties;
AND
S4.2 For Industrial business and Retail N/A Not applicable
business Type 3, materials stored outside The proposal does not involve an Industrial business or
of a building do not exceed 4m in height or Retail business Type 3.
half the height of the on-site buildings
whichever is the greater.
Safety and security Complies with probable solutions
O5 All property boundaries are clearly S5.1 Boundaries are identified by such As shown on the Architectural Proposal Plans provided
identifiable with public and private spaces means as - at Appendix C, 1.8m fencing to the side and rear
clearly defined. (a) fencing; or boundaries in addition to targeting landscape treatments
(b) changes in surface materials or levels; will ensure the property boundary will be easily defined.
or
(c) landscape treatments.
O6 All premises and access routes are S6.1 All premises are identified by the Complies
clearly identifiable to all persons, provision of the street number in a The proposals presentation and access from Eumundi
particularly emergency services personnel. prominent location, preferably near the site Noosa Rd ensures the premise will be easily identifiable
entry, (i.e. on the kerb or letterbox or by to emergency services. Please refer to the Architectural
signage on the building or site). Proposal Plans at Appendix C.
O7 All building entries are designed to be S7.1 The number of entrances and exits Complies with probable solutions
obvious and easily identifiable. are limited and main building
entrances/exits are located at the front of As shown on the Architectural Plan Package provided at
1 Solution: = Acceptable Solution Appendix H
A/S = Alternative Solution
N/A = Not applicable to this proposal
PR137996-1 November 2017 Page 2
See the original
The page text is free to read. Viewing or downloading an original file needs an account.