Skip to the record
The gold standard in government transparency.

Original source · versioned page text

Appendix B - Code Assessment Report - 6-10 Diamond Street Cooroy - 21.12.18

Attached to the e-mail Commercial Business Type 1 Office, Retail Business Type 2 Shop & Salon & Multiple Housing Type 4 Conventional - 4 units (Architectural Plans & Code Assessment Report) - MCU19/0001.

of 41

Page text shows just the words. Original shows the document exactly as it was published.

    ii for a building of 2 or more storeys - 50% on the
ground floor and 30% for the upper storey(s), or 40% for
all storeys for a building of 2 or more storeys;
b) for other classes within the Detached Housing Zone -
40%;
c) for the Semi-Attached Housing Zone—40%; or
d) for the Attached Housing Zone—40%
e) for the Community Services Zone—50%
O11 For Multiple Housing Type 2 buildings have a             No solution provided.                                           Not Applicable
maximum plot ratio of 0.45:1.                                                                                                The proposal does not include Multiple
                                                                                                                             Housing Type 2.
O12 For Multiple housing Type 3 or 4, Visitor                No solution provided.                                           Complies
accommodation Type 4, or the accommodation unit                                                                              For the Business Centre Zone– maximum
component of an Entertainment and dining business                                                                            population density of 100 persons/hectare.
Type 3—maximum gross floor area is equivalent to the                                                                         The maximum GFA for Multiple Housing
maximum allowable population in persons multiplied by                                                                        Type 4 component is 4,000m2.
40m2                                                                                                                         The proposal includes four (4) small
                                                                                                                             dwelling units, with a total 320m2 of GFA.
O13 For the Business Centre Zone plot ratio does not         No solution provided.                                           Complies
exceed—                                                                                                                      A maximum of 1,909m2 GFA is permitted
a) 0.8:1 for site areas up to and including 2,000m2 ; and                                                                    for the site. The proposed commercial
b) 0.3:1 for the balance of a site over 2,000m2 .                                                                            offices and convenience supermarket GFA
                                                                                                                             totals 697m2.
Flooding and drainage                                        S14.1 For new buildings or structures or additions of more      Complies
O14 Buildings and other works are designed and sited         than 50m2 gross floor area to an existing building or           Refer to drawing 18043-DA03 within
to—                                                          structure, floor levels for habitable rooms are—                Appendix A for details regarding floor and
a) provide flood free access to premises and flood free      a) for areas where minimum floor levels are available—not       building heights.
habitable areas;                                             less than the specified level;
b) allow only minor, short term and infrequent flooding      b) for areas where flood modelling is available—a minimum
of non-habitable areas;                                      of 300mm above the modelled flood level; and
c) ensure carparking areas can be adequately drained;        c) for areas where flood modelling is not available, a
d) ensure drainage does not adversely impact upon            minimum of 300mm above the highest known flood level;
other premises; and                                          AND
e) ensure filling or excavation does not adversely impact    S14.2 Where Council infrastructure is available—                Complies
upon other premises by—                                      a) any drainage (including buildings and yards) flows to that   The proposed development will be
   i. causing ponding of water on the site or nearby land;   infrastructure; and                                             connected to Council’s existing

                                       6-10 Diamond Street, COOROY                                                               14
Log in to download the original file

Appendix B - Code Assessment Report - 6-10 Diamond Street Cooroy - 21.12.18.pdf · 607 KB (small file)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.