Skip to the record
Beware of cheap imitations.

Original source · versioned page text

Appendix B - Code Assessment Report - 6-10 Diamond Street Cooroy - 21.12.18

Attached to the e-mail Commercial Business Type 1 Office, Retail Business Type 2 Shop & Salon & Multiple Housing Type 4 Conventional - 4 units (Architectural Plans & Code Assessment Report) - MCU19/0001.

of 41

Page text shows just the words. Original shows the document exactly as it was published.

    ii. increasing flooding, which adversely affects the      b) the infrastructure has the capacity to accept any              infrastructure.
safety or use of any land upstream and downstream;            additional loading; AND
and                                                           S14.3 Car parking and maneuvering areas are constructed at        Complies
  iii. adversely affecting the flow of water in any           a level that permits the parking area to drain from the site by   The carparking area has been designed as
overland flow path.                                           gravity means, without the need for mechanical pumping; or        to drain to Council’s existing stormwater
                                                                                                                                infrastructure.
                                                              S14.4 Basements for residential uses have flood immunity          Not Applicable
                                                              above the 1%AEP defined flood event where alternative             A basement carpark is not proposed.
                                                              means to mechanical pumping are used to achieve such
                                                              immunity;
                                                              or
                                                              S14.5 Basements for non-residential uses have flood               Not Applicable
                                                              immunity above the 1%AEP defined flood event that may be          The subject site is not affected by Council’s
                                                              achieved by means of mechanical pumping where the                 flood overlay.
                                                              mechanical feature is installed with adequate holding tanks
                                                              and an alternative back up power source.
Sloping sites                                                 S15.1 Buildings are of split level design that step down the      Not Applicable
O15 On sloping sites, buildings and structures are            slope or have a suspended floor construction; (See Figure 6.1     The subject site is of level ground.
designed to maximise the use of natural slope and             below) AND
minimise the need for cut and fill.                           S15.2 Cut or fill is less than 2m in depth; AND                   Not Applicable
                                                                                                                                No large quantities of cut and/or fill are
                                                                                                                                proposed.
                                                              S15.3 The distance between the ground and the lowest part         Not Applicable
                                                              of the floor of the building does not exceed 3m                   No under croft spaces / under buildings are
                                                                                                                                proposed.
Roof form                                                     S16.1 With the exception of industrial buildings the main         Complies
O16 Roof forms—                                               roof of the building has a roof pitch no less than 12 degrees     The proposal incorporates flat and pitches
a) contribute positively to the local skyline;                and has minimum 600mm eaves to at least 75% of the                rooves, and eaves of 650-750mm to the
b) complement the low rise character of the locality;         perimeter of the building; AND                                    western building.
c) use simple traditional roof designs, such as hipped,       S16.2 Building and structures do not include rooftop              Not Applicable
gabled or skillion; and                                       terraces.                                                         No rooftop terraces are proposed.
d) do not create opportunities for residents to overlook
the private open space areas of neighbouring properties
Public transport node                                         S17.1 A public transport node is located within Cooroy as         Complies
O17 An accessible and safe public transport node is           identified in Schedule 5 on Map 1                                 The site is well connected with major
established and operated within Cooroy that—                                                                                    transport infrastructure (Cooroy Train
                                        6-10 Diamond Street, COOROY                                                                 15
Log in to download the original file

Appendix B - Code Assessment Report - 6-10 Diamond Street Cooroy - 21.12.18.pdf · 607 KB (small file)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.