Appendix B - Code Assessment Report - 6-10 Diamond Street Cooroy - 21.12.18
Attached to the e-mail Commercial Business Type 1 Office, Retail Business Type 2 Shop & Salon & Multiple Housing Type 4 Conventional - 4 units (Architectural Plans & Code Assessment Report) - MCU19/0001.
O3 On-site water storage is designed and , outside a reticulated water service area, a rainwater tank is to The site is serviced by standard community
operated to support the efficient use of water; be installed with the following minimum storage capacities— a) infrastructure including reticulated water
AND Where no more than 3 bedrooms – 45,000 litres; or b) Where supply and sewerage.
O4 On-site water storage is adequate for more than 3 bedrooms – 60,000 litres; AND c) There is to be on Not Applicable
occupants every day use and fire fighting the lot a dam, swimming pool or water tank accessible for use by The site is serviced by standard community
purposes. the fire brigade that contains at least 5,000 litres of water. infrastructure including reticulated water
supply and sewerage.
Erosion and sediment control No solution provided. Complies
O5 Development does not cause erosion or result On site water run-off will be captured and
in transport of sediments off-site. treated on site via the landscaped features.
Safety and security S6.1 The building entrance is clearly identifiable and visible from Complies
O6 For Multiple Housing Types 2, 3 and 4, the street, footpath and driveway; AND The pedestrian entrance to each unit is
buildings and outdoor spaces are designed to clearly identifiable.
protect the personal security and safety of S6.2 The internal path network has clear sightlines to the dwelling Not Applicable
residents by allowing for natural surveillance. entry and street access points; AND No internal pathways are proposed.
Sufficient lighting will be provided for security
and safety.
S6.3 Visitors have direct access to the entrance without passing Complies
through private outdoor living areas. The design includes direct access to the
entrance of each unit via the shared balcony.
Emergency access No solution provided. Complies
O7 For Multiple housing Type 3, 4 & 5, site design The layout of the precinct results in
and layout ensures efficient access and egress for unrestricted vehicle and pedestrian access to
emergency vehicles. and egress from the site and adjacent uses.
Basement drainage S8.1 Enclosed car parking and manoeuvring areas are constructed Complies
O8 Buildings and access works are designed and at a level that permits the parking area to drain from the site by No enclosed car parking areas are proposed.
sited to protect persons and property in the gravity means, without the need for mechanical pumping.
event of a flood and power failure.
Separation of incompatible uses S9.1 Bedroom windows are at least 3m away from shared Complies
O9 Development is designed to minimise noise driveways or carparking areas of adjacent dwelling units or The proposed development has been
carrying between dwelling units or accommodation units. oriented to address the street (Diamond
accommodation units by locating noise sensitive Street) and makes a positive statement and
spaces such as bedrooms away from noise contributes to the streetscape.
generating areas of the development, such as
carparking areas or mechanic plant and
equipment or recreational facilities.