Original source · versioned page text
Appendix B - Code Assessment Report - 6-10 Diamond Street Cooroy - 21.12.18
Attached to the e-mail Commercial Business Type 1 Office, Retail Business Type 2 Shop & Salon & Multiple Housing Type 4 Conventional - 4 units (Architectural Plans & Code Assessment Report) - MCU19/0001.
controlled road. damage to Diamond Street.
PO9 Filling and excavation associated with No acceptable outcome is prescribed. Complies
the construction of vehicular access to a The proposed mixed-use precinct and
development does not compromise the associated filling, excavation and retaining
operation or capacity of existing drainage works will not interfere with or result in
infrastructure for a state controlled road. damage to Diamond Street.
PO10 Fill material used on a development AO10.1 Fill material is free of contaminants including acid sulfate Complies
site does not result in contamination of a content. Details regarding the preparation of the
state-controlled road AND site for the proposed mixed-use
AO10.2 Compaction of fill is carried out in accordance with the development will be examined within the
requirements of AS 1289.0 2000 – Methods of testing soils for documentation lodged for an Operational
engineering purposes Works Permit.
PO11 Filling and excavation does not cause AO11.1 Compaction of fill is carried out in accordance with the Complies
windblown dust nuisance in a state- requirements of AS 1289.0 2000 – Methods of testing soils for Details regarding the preparation of the
controlled road. engineering purposes. site for the proposed mixed-use
AND development will be examined within the
AO11.2 Dust suppression measures are used during filling and documentation lodged for an Operational
excavation activities such as wind breaks or barriers and dampening of Works Permit.
ground surfaces.
Stormwater and drainage
PO12 Development does not result in an No acceptable outcome is prescribed. Complies
actionable nuisance, or worsening of, The appropriate infrastructure will be
stormwater, flooding or drainage impacts in a provided. Matters regarding the treatment
state-controlled road. of water leaving the site will be address in
the Stormwater Management Plan.
PO13 Run-off from the development site is AO13.1 Development does not create any new points of discharge to a Complies
not unlawfully discharged to a state- state-controlled road. The appropriate infrastructure will be
controlled road. AND provided. Matters regarding the treatment
AO13.2 Stormwater run-off is discharged to a lawful point of discharge. of water leaving the site will be address in
AND the Stormwater Management Plan.
AO13.3 Development does not worsen the condition of an existing
lawful point of discharge to the state-controlled road.
PO14 Run-off from the development site AO14.1 Run-off from the development site during construction is not Complies
during construction does not cause siltation discharged to stormwater infrastructure for a state-controlled road. The appropriate infrastructure will be
of stormwater infrastructure affecting a provided. Matters regarding the treatment
6-10 Diamond Street, COOROY 6
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalSearchable page text hides email addresses. Original files are unchanged and may show email addresses.