Council archive · source document
Part 22 of 37 Appendix 20 - Earthcheck MCU12/0208
Very large file (86.5 MB): the whole original can take several minutes to open, especially on a phone. Text is quick to read.
The choice of appliances to be determined on basis of approved star rating system;
A target of 15% electrical energy use reductions regarding air conditioning units used
in retail, recreational and community buildings;
A target of 20% reduction in electrical energy consumption of air conditioning system
pumps via variable volume pumping where applicable;
For residential buildings:
Design strategies to exploit orientation, materials, shading and passive heating on all
residential lots to reduce energy footprint;
Residential dwellings targeted to achieve an average Building Energy Rating of 5
stars;
The use and maintaining of adequate setbacks particularly lake frontage areas;
All dwellings to be fitted with efficient (preferably gas, solar or heat pump) hot water
systems;
The choice of domestic appliances to be determined on basis of approved star rating
system.
Water Conservation and Management
Water conservation and management is now crucial to all precincts. At Noosa on Weyba the
Client-Developer has committed to an integrated water cycle management strategy. A high
value is being placed on security and quality of supply along with the exploiting of a wide
range of opportunities for water conservation and management. The requirements of the
development mean recognition must be given to the need for it to be managed to reduce
demand high quality municipal potable water supplies and
on to encourage the use of
sustainable water supplies such as rainwater capture and reuse.
There is a documented commitment to monitor the overall efficiency of potable water usage
with a view to promoting reduction without compromising the operation. Further a
construction management strategy exists for the minimizing of consumption of potable water
during all precinct building activities.
These opportunities include:
A specific target reduction in the town water supplied or consumed of 30% on water
use through a combination of water efficiency and reuse options;
A target of 100% of rain water to be harvested from all roof areas;
Development strategies for the reduction of construction water usage to be developed
and encouraged; (i.e. prefabrication, material selection)
Education and awareness programmes are to be created on water conservation for all
residents, visitors and precinct management staff.
Note: Whilst desirable treated grey water (via sewer mmmg and treatment to
potable quality) usage for all open space and recreational infrastructure buildings
has not been adopted because of the highly sensitive nature of the surrounding
lakeside environment, therefore all buildings will be connected to the existing town
sewer system;
12
EC3 (Earthcheck)Prec nct Plann ng and Des gn Standard (PPDS)for Prec ncts. Cert cat on Report
@ 2007 EC3 Asia Pacific. All rights reserved. Version EC3 PPOS 2012.
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Part 22 of 37 Appendix 20 - Earthcheck MCU12/0208Related documentApplication case desk ↗