Original source · versioned page text
Appendix C - Code Response - Low Density Housing Code
Noosa Plan 2020: Amendment 3
Part 9 Development codes \ 9.3 Use Codes \ 9.3.1 Low Density Housing Code
driveway and cross-over is located to provide minimum
safe sight distances in accordance with Austroads.
Editor's Note - An operational works application is required
for a second driveway.
Earthworks and drainage
Earthworks and Drainage AO15 N/A
PO15 Filling other than accessways: The development is for a shed only and will not
Earthworks and drainage operational works do not (a) does not extend more than the equivalent of 1.5 involve earthworks. The site is subject to a historical
directly, indirectly or cumulatively cause adverse metres within the urban area boundary and 3m subdivision in which site works were previously
impacts external to the development site by: for rural areas, measured from the outer walls of undertaken and the proposed shed will be located on
(a) causing ponding of water on the site or nearby the main building; a flat section of site.
land; (b) is limited to a maximum of 500m2; and
(b) increasing flooding, which adversely affects the (c) does not impact on the local drainage of
safety or use of any land upstream and adjoining properties.
downstream;
(c) adversely affecting the flow of water in any
overland flow path; and
(d) adversely affecting the privacy or visual amenity
of surrounding property.
Editor's Note—Development should ensure that filling does
not impact on the amenity and usability of neighbouring
properties (including loss of privacy caused by relative level
changes) or offsite drainage.
PO16 No acceptable outcome provided N/A
Underground car parking areas are designed to drain Not listed as an assessment benchmark under Table
and function safely during a flood event and power 5.5.14.
failure.
Editor's note—Basements should have flood immunity
above the 1%AEP defined flood event with alternative means
to mechanical pumping used to achieve such immunity.
Hazards
Bushfire Hazard Management AO17 ✓
PO17 Within a bushfire hazard area where there is no The site is not serviced via water mains
Where located in a Bushfire Hazard Area as shown on reticulated water supply, the premises has: infrastructure and will utilise on-site rainwater tanks
the Bushfire Hazard Overlay Map in Schedule 2 and (a) an accessible dam, swimming pool or water tank as per the prescribed minimum requirements.
Print Date: 23/03/2026 Page 7
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the original