not in a water service area, an adequate, reliable, available for firefighting purposes with an onsite
safely located and freely accessible water supply is water volume of not less than 5,000 litres; and
provided for fire fighting purposes, which is in addition (b) a water supply outlet pipe 50 millimetres in
to day to day water supply. diameter and fitted with a standard fire brigade
fitting connected to the water supply (other than
where the water supply is in a swimming pool or
dam).
Editor’s Note — Water supply capacity for firefighting
purposes is in addition to water supply capacity for
household use.
Flood Hazards AO18.1 N/A
PO18 Where the development is located in the Flood Hazard The proposed development is not located in a flood
Development is designed and sited to ensure risk to Area as shown on Flood Hazard Overlay Map in hazard overlay area.
people and property from flooding is avoided or Schedule 2, the finished floor level of habitable rooms
minimised. is at least 300 millimetres above the Defined flood
event (DFE).
OR
AO18.2
Where the DFE has not been modelled for the area,
the finished floor level of habitable rooms is at least
500 millimetres above the highest recorded flood.
Editor's Note—The QDC mandatory provisions MP3.5 also
apply to the construction of buildings in flood hazard areas.
Landslide Hazard Area AO19.1 N/A
PO19 Development, including associated access, is not The proposed development is not located in a
Development maintains the safety of people, property located on land identified as a landslide hazard area landslide hazard area or on steep land.
and hazardous materials stored in bulk from the risk of on a Landslide Hazard Overlay Map or areas with 15%
landslide. slope or greater, as determined by a site-specific
slope-analysis
Editor's Note—A site- specific geotechnical assessment
may be used to demonstrate that although the proposed
development is shown on the Landslide Hazard Overlay as
being in the moderate, high or very high landslide hazard
area, the landslide risk is low or very low.
OR
AO19.2
A site-specific geotechnical assessment is prepared by