Operational Management Plan 2015
Attached to the e-mail MCU14/0096 Applicants Response to SARA's Information Request.
Plans and drawings
This document appears to be plans or drawings. Its page text below holds only the words printed on the drawings, without the drawings themselves, so it may be jumbled or hard to follow. To see the plans as drawn, choose Original above or download the file (both need you to log in).
Log in to see the plans as drawn5.2 Water quality reaction plan
Water quality Low High Emergency Plan
Parameter setpoint setpoint
PH 7.8 8.2 Manually test and adjust with
Hydrated lime to increase PH or
Hydrochloric Acid to decrease PH
Ammonia (TAN) N/A 1ppm Inspect grow tanks for dead fish
Inspect Bio filter for correct
operation.
Reduce feed rate equal to the
date of last acceptable ammonia
test. Increase feed rate at slower
rate to allow bio filter bacteria to
grow. If ammonia levels increase
to high levels ensure there is
enough bio media in bio filter.
Nitrite NO2 N/A 1ppm Check De nitrification tank for
correst dosing of carbon donor
and ORP level correct to ensure
there is no nitrite build up in de
nitrification tank outlet.
Inspect Bio filter for correct
operation.
Reduce feed rate equal to the
date of last acceptable ammonia
test. Increase feed rate at slower
rate to allow bio filter bacteria to
grow. If ammonia levels increase
to high levels ensure there is
enough bio media in bio filter.
Nitrate NO3 N/A 200ppm Check denitrification for correct
operation. Check for correct ORP
reading. Ensure at 3% of system
water is being discharged.
Decrease feed rate until solution
is found.
ORP (Outlet of +300mv +350mv If below 300mv check ozone
protein skimmer to generator for correct operation
control ozone including ORP Probe. Check
output) oxygen generator that produces
oxygen for the ozone generator.
If above 350mv turn ozone
generator off immediately. Check
ORP probe and recalibrate then
turn on ozone generator and
monitor for correct operation.
ORP (de nitrifying -50mv +50mv If below -50mv check dosing
tank to control pump for correct operation and