Skip to the record
For the highest quality transcripts.

Original source · versioned page text

Operational Management Plan 2015

Attached to the e-mail MCU14/0096 Applicants Response to SARA's Information Request.

of 12

Page text shows just the words. Original shows the document exactly as it was published.

Plans and drawings

This document appears to be plans or drawings. Its page text below holds only the words printed on the drawings, without the drawings themselves, so it may be jumbled or hard to follow. To see the plans as drawn, choose Original above or download the file (both need you to log in).

Log in to see the plans as drawn
carbon         donor                                check Nitrite levels in system
dosing)                                             water to ensure nitrite levels are
                                                    not at high levels. If above +50mv
                                                    check oxygen level in tank to
                                                    ensure it is <2mg/l check flow rate
                                                    to ensure there is a 2hr dwell time
Carbon Dioxide CO2 N/A                20mg/l        Check maintenance log to Ensure
                                                    probe has been recalibrated to
                                                    manufacturers recommendations.
                                                    Check protein skimmer and
                                                    MBBR for correct air flow to
                                                    ensure CO2 is being gassed off.
Dissolved Oxygen       4mg/l          N/A           When low set point triggered turn
                                                    on manual bottled oxygen to feed
                                                    oxygen into emergency diffusers
                                                    in grow tanks immediately. Check
                                                    oxygen generator for correct
                                                    operation. Check water flow is
                                                    sufficient in grow tank that has low
                                                    oxygen. Clean oxygen probe,
                                                    check membrane for damage and
                                                    check maintenance log to ensure
                                                    probe has been calibrated to
                                                    manufacturers recommendations.
Salinity               13ppt          22ppt         Check storage tank to ensure
                                                    supply water is correct salinity
                                                    then adjust accordingly
Temperature            25C            33C           Check heater/ chiller for correct
                                                    operation


6 Biosecurity
6.1 Animal source

Animals should be obtained from disease-free farms or sources only, after
appropriate health testing and disease-free certification by a reputable veterinary
laboratory; disinfect eggs or larvae where appropriate, quarantine (isolate) all animal
introductions from the rest of the farm for an appropriate period of time. The length of
quarantine time depends on the species of aquatic animal and potential disease or
parasite. Contact DPI&F veterinary and extension officers for advice.
b) Seek advice on appropriate preventative treatments for parasites to all introduced
animals while still in quarantine.

6.2 Hygiene

a) Seek advice on the disinfection of eggs or larvae prior to use.
b) Remove sick and dying animals as soon as possible and treat in a quarantine
section or dispose of appropriately, so there is no contamination of the farm animals
or aquatic environment.
Log in to download the original file

Operational Management Plan 2015.pdf · 308 KB (small file)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.