Original source · versioned page text
Att3 - Bushfire Report
Very large file (10.0 MB): the original may take a few minutes to open or download. The page text below is quick to read.
Bushfire Hazard Assessment & Management Plan v1 NCES REF: J001061
Lot 7 on RP216403, Lot 394 on M371117, and Lot 650 on M37380 – 48-59 Kabi Road, Cootharaba
Table 5 – Table 8.2.3.3 Bushfire Hazard Areas – Part 8 Overlay Code Noosa Plan 2020
PERFORMANCE OUTCOMES ACCEPTABLE OUTCOMES PROPOSED SOLUTION
Safety of people and property
PO1 AO1.1 This Bushfire Hazard Assessment and Management Plan has been prepared to
Development maintains the safety of people and Development which will materially increase the number of people maintain the safety of people and property from the adverse impacts of bushfire.
property from the adverse impacts of bushfire. living or congregating on premises, including reconfiguring a lot, is not
AO1.1 –The proposed development footprint is entirely located outside of a
located within a medium or high bushfire hazard area.
mapped medium or high bushfire hazard area as depicted on the Local Hazard
Area Map BF03 & BF04.
AO1.2
Development maximises setbacks from hazardous vegetation to AO1.2 – The development has provided minimum setbacks between the
achieve an acceptable risk. proposed buildings and hazardous vegetation to achieve the SPP Assessment
Benchmark 3 ‘vulnerable use ‘criteria of <10kW/m2 radiant heat flux exposure.
Editor’s Note —PSP8 Natural Hazards provides guidance for This setback achieves an acceptable risk where all the mitigation measures
assessing bushfire hazard risk and preparing a bushfire hazard detailed within this report are employed.
management plan.
Impact on Ecologically Important Areas
PO2 No acceptable outcome provided The bushfire mitigation measures prescribed herein will not adversely impact on
Bushfire mitigation measures do not adversely impact biodiversity values, connectivity, ecosystem functioning, and the long-term
on: physical integrity of waterways, wetlands and areas of native vegetation.
Minor edge clearing of an existing modified vegetation unit may be required
a) biodiversity values, connectivity and ecosystem along the roadway to ensure the risk of access/egress becoming constrained
functioning; and during a bushfire event is low (i.e., to establish the recommended minimum 10m
wide cleared area, inclusive of the roadway).
b) the long term physical integrity of waterways, wetland
and areas of native vegetation.
Water Supply for Fire Fighting Purposes
PO3 AO3.1 AO3.1 – No reticulated water is currently available to the site. The water supply
Development provides an adequate water supply for Premises are connected to the reticulated water supply. requirements of SPP Assessment Benchmark 4 prevails; 10,000KL per new
firefighting purpose which is reliable, safely located and building located within a confirmed bushfire prone area. In this instance the
freely accessible. Editor's note—For reconfiguring a lot, water supply needs to provide proposed buildings (recreation & central hall and three villages) are located
for a minimum flow and pressure of 10 litres a second at 200kPa at all outside of a confirmed bushfire prone area hence specific emergency static
times for firefighting purposes. water supply for these buildings is not required by the SPP.
Note, the reliance upon dams or pools for water storage is not an acceptable
OR
solution under the SPP.
AO3.2
Where there is no available reticulated water supply, the premises
has:
a) an accessible dam, swimming pool or water tank available for
firefighting purposes with an onsite water volume of not less than
5,000 litres; and
b) a water supply outlet pipe 50 millimetres in diameter fitted with a
standard fire brigade fitting connected to the water supply (other than
where the water supply is in a swimming pool or dam).