SELECT HORIZONTAL CLADDING ROOF TRUSSES & BRACING STONE CLADDING 'ROOF TRAY' WITHIN AWNINGS ROOF FRAMING & BRACING TO
FIXED TO MANUFACTURER'S SPEC. TO MANUFACTURER'S SPEC. TO MATCH EXISTING INSTALLED TO MAN. SPEC. STRUCTURAL ENGINEER'S SPEC.
HARDIES 300 STRIA OR SIMILAR FRAMING TO ENG. SPEC.
18.0°
NOTES:
SIDE BOUNDARY LINE
SIDE BOUNDARY LINE
2,000 MIN.
18.0° TO FASCIA 1. ALL GROUND LEVELS ARE APPROXIMATE ONLY.
600
2. ALL STAIRS ARE TO HAVE 190mm MAX. RISERS
AND 250mm MIN. GOINGS
GAS FLUE INSTALLED TO 3. PROVIDE SILL AND JAMB FLASHING TO ALL WINDOWS
MAN. SPEC. & AS5601 AND DOORS TO MANUFACTURER'S SPECIFICATION
OPENING HEAD HEIGHT
FLOOR TO CEILING
(EXCEPT STUDY)
RENDER FINISH OVER SELECT TIMBER BALUSTRADE AND
2,700
FOAMBOARD CLADDING 4. ALL WORKS ARE TO BE CONSTRUCTED IN ACCORDANCE
2,400
PAINTED FINISH TO OWNER'S SPEC.
WITH THE CURRENT NCC AND IT'S AMENDMENTS,
LOCAL AUTHORITIES AND IN ACCORDANCE TO
RELEVANT TRADE AND TECHNICAL MANUALS
RL 5.460 5. ROOF BRACING TO BE IN ACCORDANCE WITH
1,470
OPENING HEAD HEIGHT LINTEL
590
MANUFACTURER'S/ENGINEER'S SPECIFICATION
existing
FLOOR TO CEILING
OPENING HEAD HEIGHT
(GARAGE DOOR)
(MIN..)
2,700
(EXISTING)
2,410
2,100
EXISTING
SIDE GATE
STRUCTURAL
SLAB LEVEL
RL 2.460
EXISTING G.L EXISTING ALUM. RE--USE EXISTING RENDER FINISH OVER FIXED GLASS PANELS
POOL FENCE & GATE METAL GATE & SCREENS BLOCKWORK WALLS IN PANELIFT DOOR
PROPOSED
NORTHEAST ELEVATION (1)
SEMI--FRAMELESS 1000H GLASS BALUSTRADE GAS FLUE INSTALLED TO SELECT COLORBOND CUSTOM ORB ROOF ROOF TRUSSES & BRACING
INSTALLED TO MANUFACTURER'S SPEC. MAN. SPEC. & AS5601 SHEETING FIXED TO MANUFACTURER'S SPEC. TO MANUFACTURER'S SPEC.
8.0m HEIGHT LIMIT
21° PITCH SELECT POWDERCOATED ALUMINIUM FRAMED
600
KING TRUSS WITH PURLINS WINDOWS AND DOORS INSTALLED TO MAN. SPEC.
ABOVE TO ENGINEER'S SPEC. (TO MATCH EXISTING)
SELECT METAL FASCIA & GUTTER
INTERNAL STRUCTURAL FLOOR
SELECT P.C. ALUM. INSTALLED TO MAN. SPEC.
TO U/SIDE KING TRUSS
BATTEN SCREEN (TBC)
2,700 MAX.
EXISTING RENDER FINISH OVER
380x100 PFC BEAMS FOAMBOARD CLADDING
380 PFC
EXIST.
SELECT HORIZONTAL CLADDING
RL 5.810
FIXED TO MANUFACTURER'S SPEC.
HARDIES 300 STRIA OR SIMILAR
DIMENSION (INTERNAL)
ALF. SLAB TO U/SIDE PFC
STRUCTURAL FLOOR
3,370/3,390
REINSTATE
FLOOR TO CEILING
STONE CLADDING
3,000
(MIN..)
2,700
20
NGL
FALL TO
30
EXT. SLAB NOTE:
EXISTING EXISTING G.L EXISTING GLASS PORTION OF EXIST. PARAPET WALL RENDER FINISH OVER EXISTING ALUM. HARDIES SCYON AXENT TRIM OR SIMILAR
150x100 RHS POOL FENCE & GATE TO REMAIN (CONFIRM ON SITE) BLOCKWORK WALLS POOL FENCE & GATE INSTALLED TO MANUFACTURER'S SPEC.
PROPOSED AROUND WINDOWS & DOORS WHERE
LIGHTWEIGHT CLADDING IS USED.
SOUTHEAST ELEVATION (2)
FOR QUOTING
BRIGHT
MARK TEUNON CLIENT PROJECT
BAR SCALE m. 0402 750 622 HUGH & JO ENGLISH PROPOSED EXTENSIONS JOB No: 22.006
e. [email protected] SITE ADDRESS DRAWING issued: 31.12.22 DRAWING No:
0 1 2 3 4 5 10
BUILDING DESIGN QBCC Lic. No. 1271669 No. 8 RAVENWOOD DRIVE PROPOSED ELEVATIONS 1+2 drawn: MJT
11
CUSTOM DESIGN & QUALITY DRAFTING ABN: 73 072 707 632 NOOSA HEADS scale: 1:100 (A3)
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
231587 - 8 Ravenwood Dr Noosa Heads - Alterations and Additions to Dwelling - Archs.pdfRelated documentApplication case desk ↗
About this file
- File size
- 4.0 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.