SELECT HORIZONTAL CLADDING
FIXED TO MANUFACTURER'S SPEC. KING TRUSS WITH PURLINS
SIDE BOUNDARY LINE
SIDE BOUNDARY LINE
HARDIES 300 STRIA OR SIMILAR ABOVE TO ENGINEER'S SPEC. NOTES:
1. ALL GROUND LEVELS ARE APPROXIMATE ONLY.
2. ALL STAIRS ARE TO HAVE 190mm MAX. RISERS
AND 250mm MIN. GOINGS
3. PROVIDE SILL AND JAMB FLASHING TO ALL WINDOWS
OPENING HEAD HEIGHT
FLOOR TO CEILING
(EXCEPT STUDY)
1502 SHS COLUMNS AND DOORS TO MANUFACTURER'S SPECIFICATION
TO ENG. SPEC.
2,700
2,400
4. ALL WORKS ARE TO BE CONSTRUCTED IN ACCORDANCE
WITH THE CURRENT NCC AND IT'S AMENDMENTS,
LOCAL AUTHORITIES AND IN ACCORDANCE TO
EXISTING RELEVANT TRADE AND TECHNICAL MANUALS
380x100 PFC BEAMS
5. ROOF BRACING TO BE IN ACCORDANCE WITH
MANUFACTURER'S/ENGINEER'S SPECIFICATION
EXISTING
FLOOR TO CEILING
OPENING HEAD HEIGHT
150x100 RHS
(MIN..)
2,700
2,100
EXISTING GLASS
POOL FENCE & GATE
RENDER FINISH OVER EXISTING EXISTING EXISTING G.L
BLOCKWORK WALLS 150x100 RHS TIMBER SCREEN
PROPOSED
SOUTHWEST ELEVATION (3)
ROOF FRAMING & BRACING TO GAS FLUE INSTALLED TO ROOF TRUSSES & BRACING SELECT HORIZONTAL CLADDING SELECT COLORBOND CUSTOM ORB ROOF
STRUCTURAL ENGINEER'S SPEC. MAN. SPEC. & AS5601 TO MANUFACTURER'S SPEC. FIXED TO MANUFACTURER'S SPEC. SHEETING FIXED TO MANUFACTURER'S SPEC.
(STUDY) HARDIES 300 STRIA OR SIMILAR
GAS FLUE INSTALLED TO
MAN. SPEC. & AS5601
600
SELECT METAL FASCIA & GUTTER
INSTALLED TO MAN. SPEC.
SELECT BATTEN
RENDER FINISH OVER BALUSTRADE/SCREEN (TBC)
FOAMBOARD CLADDING
EXISTING
380x100 PFC BEAMS
380
PFC
RL 5.810
EXISTING
ALF. SLAB TO U/SIDE PFC
150x100 RHS
3,000
NOTE:
EXIST. TIMBER EXISTING G.L RENDERED HARDIETEX CLADDING RENDER FINISH OVER SELECT POWDERCOATED ALUMINIUM FRAMED HARDIES SCYON AXENT TRIM OR SIMILAR
FENCE & GATE OR SIMILAR. FIXED TO MAN. SPEC. BLOCKWORK WALLS WINDOWS AND DOORS INSTALLED TO MAN. SPEC. INSTALLED TO MANUFACTURER'S SPEC.
PROPOSED (TO MATCH EXISTING)
AROUND WINDOWS & DOORS WHERE
LIGHTWEIGHT CLADDING IS USED.
NORTHWEST ELEVATION (4)
FOR QUOTING
BRIGHT
MARK TEUNON CLIENT PROJECT
BAR SCALE m. 0402 750 622 HUGH & JO ENGLISH PROPOSED EXTENSIONS JOB No: 22.006
e. [email protected] SITE ADDRESS DRAWING issued: 31.12.22 DRAWING No:
0 1 2 3 4 5 10
BUILDING DESIGN QBCC Lic. No. 1271669 No. 8 RAVENWOOD DRIVE PROPOSED ELEVATIONS 3+4 drawn: MJT
12
CUSTOM DESIGN & QUALITY DRAFTING ABN: 73 072 707 632 NOOSA HEADS scale: 1:100 (A3)
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
231587 - 8 Ravenwood Dr Noosa Heads - Alterations and Additions to Dwelling - Archs.pdfRelated documentApplication case desk ↗
About this file
- File size
- 4.0 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.