            Risk Assessment

                                        Risk                                   Risk Mitigation
                                   Surface Runoff                                  Mounds
                                   Human Contact                   Signs and mound to identify area. Apply by
                                                                                   setbacks
                        Overloading of system and LAA                Use correct DIR, flow allowances and
                                                                             maximum occupancy

            Recommendations

                 • An approved Advanced Secondary ASTP is to be installed. (Installer to ensure tank
                   position does not damage to existing or proposed structures)
               • A covered surface irrigation area of 240m2 consisting of pressure compensating lines
                   laid atop of the existing ground surface level and spaced approximately 800-1000mm
                   apart and covered with 150mm of mulch.
               • The tank must be installed and anchored if necessary, to prevent flotation.
               • Installer to confirm sufficient fall is available to the treatment plant prior to installation once
                   the floor height is known.
               • Top of treatment plant shall be at least 150mm above any flood levels that are present.
               • A filter must be installed in between treatment plant and irrigation area.
               • Pump must have sufficient power to pressurise irrigation lines.
               • All pipework and fittings used must meet relevant Australian Standards be buried, withstand
                   150% of pump shut-off-head and be fit for use.
               • The supply line from the treatment plant to the irrigation area shall be buried 25-32mm
                   purple line poly within a 200mm layer sand bed to prevent damage.
               • A flush out valve should be installed on the end of the irrigation area and used regularly.
               • Flexible joints should be used from the treatment to the proposed/existing structure where
                   the site is “H1” or higher.
               • A reserve area equal to the above area is to be kept free of development and vehicle traffic
                   as per plan.
               • The area shall be surrounded by a 150mm high earth mound.
               • The area shall be mulched to a depth of 150mm, and evergreen plants planted to maximise
                   evapotranspiration.
               • Two signs are to be erected stating ‘Recycled water-buried pipes-Do not dig’
               • All Storm water from the residence and uphill slopes is to be diverted away from the area.
               • Set back distances as per local council policies and AS1547 -2012 are to be met some of
                   these setbacks when Advanced Secondary ASTP with Surface Irrigation are;
            10M from a watercourse, dam, table drain, bore etc.
            10M from a dwelling or habitable building.
            2M from a boundary/driveway if it slopes away or is level with that boundary/driveway.
            4M from boundary/driveway if it slopes towards that boundary/driveway
            6M from an inground water tank
            6M from pool edge.
            Authorised Signatory

            Matthew Bennett
            on behalf of Ground Drill Pty Ltd
            QBCC Lic # 15034580




Document Set ID: 21426326
Version: 1, Version Date: 24/03/2021
Log in to download the original file

Combined Approved Plans RAL21_0003.pdf · 12.4 MB (very large file)

Very large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.