Original source · versioned page text
Attachment 1D - UNITS 6-7
Attached to the e-mail Development Application MCU - 226 David Low Way Peregian Beach Units 6-7(Email 6).
GENERAL NOTES PEREGIAN BEACH VILLAS UNITS 6-7 , 226 DAVID LOW WAY, PEREGIAN BEACH, SUNSHINE COAST, QLD, CONTRACTOR TO CONFIRM ALL DIMENSIONS, LEVELS AND GENERAL SITE CONDITIONS INCLUDING LOCATION OF EXISTING SERVICES ON SITE PRIOR TO THE COMMENCEMENT OF ANY WORKS. DRAWINGS TO BE READ IN ASSOCIATION WITH SPECIFICATION AND SCHEDULES OF FINISHES. DIMENSIONS TAKE PRECEDENCE OVER SCALE. DO NOT SCALE FROM DRAWINGS. REFER ANY DISCREPANCIES DIRECTLY TO THE SUPERINTENDENT. REFER TO STRUCTURAL ENGINEERS DRAWINGS FOR ALL FOOTINGS, SLAB AND WALL DETAILS AND SIZING OF STRUCTURAL MEMBERS. REFER TO SPECIFICATION FOR RELEVANT AUSTRALIAN STANDARDS. 5,315 250 5,315 PROTECTION FROM TERMITES IS TO BE INSTALLED IN ACCORDANCE WITH AS3660.1-2000. AND PART 3.1.3 OF THE BCA. 90 2,835 90 2,300 250 2,300 90 1,445 90 1,300 90 STAIRS, HANDRAILS AND BALUSTRADES TO BE IN ACCORDANCE WITH THE B.C.A. ALUMINIUM WINDOWS TO BE IN ACCORDANCE WITH AS2047 AND 90 90 AS2048 AND CLEAR GLAZING IN ACCORDANCE WITH AS1288 AND AS2208 AND THE DESIGN CONDITIONS AS NOMINATED. 90 90 BUILDER IS RESPONSIBLE FOR WATERTIGHTNESS OF THE BUILDING AND MUST PROVIDE FLASHING, SARKING REQUIRED TO PREVENT THE ENTRY OF MOISTURE INTO THE BUILDING. 3,585 3,495 Outdoor Living Outdoor Living WATERPROOFING TO WET AREAS IN ACCORDANCE WITH SECTION 3.8.1 OF THE B.C.A AND AS 3740 4.8 x 2.5 4.8 x 2.5 ALL BUILDING WORK SHALL COMPLY WITH THE BCA, LOCAL AUTHORITY REGULATIONS & ALL RELEVANT AUSTRALIAN STANDARDS. REFER LANDSCAPE ARCHITECT PLANS FOR LANDSCAPE WORKS 90 90 SMOKE ALARMS ARE TO BE HARDWIRED AND IN ACCORDANCE WITH AS3788 & PART 3.72 OF THE BCA 8,580 8,580 Living Living CONCEAL ALL VENT PIPES AND WASTE PIPES WITHIN WALL FRAMING 4.8 x 2.4 4.8 x 2.4 MAX BUILDING HT ABOVE NATURAL GROUND LINE IS TO BE 8500 mm Bay Window Bay Window 16 16 AND IN ACCORDANCE WITH BBC DEVELOPMENT APPROVAL REQUIREMENTS 4,486 4,486 15 15 12,640 14 14 12,800 13 13 SET DOWN FLOOR JOISTS TO ALL UPPER LEVEL BATHROOMS / WET 12 12 AREAS FOR FLUSH FLOOR FINISH BETWEEN POLISHED TIMBER 11 11 FLOORS AND TILED FLOORS - REFER STRUCTURAL ENG DRAWINGS FOR MEMBER SIZES 10 10 Kitchen Kitchen 9 8 2.8 x 3.0 2.8 x 3.0 9 8 LEGEND 7 7 A/C AIR CONDITIONING AS SPEC. - INSTALLED 90 90 6 6 BY CONTRACTOR AP 450 X450 REMOVABLE ACCESS 510 510 5 5 4 4 PANEL - LOCATION TO BE CONFIRMED ON SITE BL CONC. BLOCK WALL TO STRUCTURAL ENG. 90 90 90 90 3 3 DETAIL - RENDER AND PAINT AS SPEC. 2 2 CF COLORBOND FLASHING TO DETAIL 1 1 CJ CLADDING CONTROL JOINT - REFER ELEVATIONS CONC CONCRETE SLAB TO ENG. DETAIL CPD CUPBOARD Study Study DP 90mm DIA DOWNPIPE AS SPEC. 3,000 3,000 3.7 x 3 3.7 x 3 REFER TO DETAILS FOR TYPICAL FIXING DRY CLOTHES DRYER DW DISHWASHER EG COLORBOND EAVES GUTTER TO PROFILE SHOWN WITH WC WC GUTTER BRACKETS @ MAX 900 CRS EGL EXISTING GROUNDLINE F REFRIGERATOR 90 90 FW FLOOR WASTE Balcony Balcony GD S.S GRATED DRAIN AS SPEC. HC HOSE COCK - REFER FLOOR PLANS FOR LOCATION HP HOT PLATES AS SPEC. 930 930 HWU HOT WATER MR MECHANICAL RISER MW MICROWAVE 250 NGL NATURAL GROUND LINE 500 90 3,670 90 965 965 90 3,670 90 500 OV OVEN P PANTRY PGL PROPOSED GROUNDLINE 4,815 250 4,815 PTF POLISHED TIMBER FLOOR AS SPEC. RHS RHS TO STRUCTURAL. ENG. DETAIL RV "WIRILY BIRD" OR SIM. APPROVED S SINK SD HARDWIRED SMOKE DETECTOR TO COMPLY WITH A.S. 3786-1993 SHR SHOWER TO DETAIL SHS SHS TO STRUCTURAL. ENG. DETAIL SL SKYLIGHT AS SPEC. T TUB T-1 INTERNAL TILE AS SPEC. T-2 EXTERNAL TILE AS SPEC. TD HWD TIMBER DECKING AS SPEC. TOW TOP OF WALL VAC IN-BUILT VACUUM SYSTEM AS SPEC. VB VANITY BASIN WC TOILET SUITE WF COLORBOND WALL FLASHING WM WASHING MACHINE Amendments Wind Rating Checked By: Status: PR Date: 22-01-14 PEREGIAN BEACH VILLAS A 06.12.13 Preliminary Client Approval CT Scale: 1:100 @ A3 Drawn by: CT Client Signiture Approval: C 11.12.13 Revised site plan + amendments CT Client Initials: TBC ALEX CHARLWOOD Drawing Title: D 16-01-14 Amend GFA CT Date: UNITS 6-7 , 226 DAVID LOW WAY, PEREGIAN BEACH, SUNSHINE COAST, QLD, E 22-01-14 Client request amendments CT PH: 0410 650 745 FIRST FLOOR BSB No.: 1043429 NOTES: ABN: 59 980 573 352 Client: Drawing No.: PR Drawings by HINTON STEEL FRAME QLD PTY LTD. ECO REMOTE A.01.3 E ALL PLANS ARE COPYRIGHT AND MAY NOT BE REPRODUCED IN WHOLE OR AND PART WITHOUT WRITTEN PERMISION FROM HINTON STEEL FRAMES
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Large file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.