Original source · versioned page text
Attachment 1D - UNITS 6-7
Attached to the e-mail Development Application MCU - 226 David Low Way Peregian Beach Units 6-7(Email 6).
ELEVATION LEGEND PEREGIAN BEACH VILLAS UNITS 6-7 , 226 DAVID LOW WAY, PEREGIAN BEACH, SUNSHINE COAST, QLD, D-0 WD-0 DOOR NUMBER WINDOW NUMBER CF CLADDING FINISH ABBREVIATIONS AC AIR-CONDITIONING Roof sheets @ 140 pitch fixed in ALY ALYSNITE FLAT SHEETING BLK BLOCKWORK accordance with manufactures FL CN CONCRETE specification Roof sheets @ 120 pitch fixed DP1 90Ø DOWNPIPE in accordance with EG1 EAVES GUTTER MRS FC FIBRE CEMENT WITH 10mm EXPRESSED manufactures specification MRS JOINTS Bay window, with specified cladding fixed EG1 FCC COMPRESSED FIBRE CEMENT in accordance with manufactures FL FLASHING Ceiling Level specification Ceiling Level LVF FIXED ALUMINIUM LOUVRE EG1 FL MRS METAL ROOF SHEETING FL ZINC ZINC CLADDING WITH STANDING SEAM Aluminium framed windows NGL NATURAL GROUND LINE fixed to manufactures PLY PLYWOOD WITH 10mm EXPRESSED specifications 2,740 2,740 JOINTS Timber ballustrade, in accordance with the SPR SPREADER BCA and relevant Aus Standards SPT SPITTER Floor Level Timber screen Floor Level Ceiling Level Ceiling Level Steel post in accordance with engineers specifications Aluminium screen, in 2,740 2,740 accordance with manufacteres Specified cladding fixed in accordance with specifications manufactures specification Slab Level NGL NGL Slab Level 1 Left Elevation 1:100 Roof sheets @ 140 pitch fixed MRS MRS in accordance with manufactures specification Ceiling Level Ceiling Level EG1 EG1 Bay window with specified horizontal cladding fixed in accordance with manufactures specification Timber ballustrade, in 2,740 2,740 accordance with the BCA and Aluminium framed bifold windows beyond relevant Aus Standards fixed to manufactures specifications Floor Level Floor Level Ceiling Level Ceiling Level Specified vertical cladding fixed in accordance with manufactures Fire rated wall in accordance specification with manufacturers 2,740 2,740 specifications Steel post in accordance with engineers specifications Slab Level NGL NGL Slab Level 2 Rear Elevation 1:100 Amendments Wind Rating Checked By: Status: PR Date: 22-01-14 PEREGIAN BEACH VILLAS A 06.12.13 Preliminary Client Approval CT Scale: 1:100, 1:353.41 @ A3 Drawn by: CT Client Signiture Approval: C 11.12.13 Revised site plan + amendments CT Client Initials: TBC ALEX CHARLWOOD Drawing Title: D 16-01-14 Amend GFA CT Date: UNITS 6-7 , 226 DAVID LOW WAY, PEREGIAN BEACH, SUNSHINE COAST, QLD, E 22-01-14 Client request amendments CT PH: 0410 650 745 ELEVATIONS BSB No.: 1043429 NOTES: ABN: 59 980 573 352 Client: Drawing No.: PR Drawings by HINTON STEEL FRAME QLD PTY LTD. ECO REMOTE A.01.4 E ALL PLANS ARE COPYRIGHT AND MAY NOT BE REPRODUCED IN WHOLE OR AND PART WITHOUT WRITTEN PERMISION FROM HINTON STEEL FRAMES
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Large file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.