Original source · versioned page text
Attachment 1D - UNITS 6-7
Attached to the e-mail Development Application MCU - 226 David Low Way Peregian Beach Units 6-7(Email 6).
ELEVATION LEGEND PEREGIAN BEACH VILLAS UNITS 6-7 , 226 DAVID LOW WAY, PEREGIAN BEACH, SUNSHINE COAST, QLD, D-0 WD-0 DOOR NUMBER WINDOW NUMBER CF CLADDING FINISH ABBREVIATIONS AC AIR-CONDITIONING ALY ALYSNITE FLAT SHEETING 0 Roof sheets @ 14 pitch fixed in BLK BLOCKWORK accordance with manufactures CN CONCRETE FL DP1 90Ø DOWNPIPE specification Roof sheets @ 70 pitch fixed EG1 EAVES GUTTER in accordance with FC FIBRE CEMENT WITH 10mm EXPRESSED manufactures specification MRS JOINTS MRS FCC COMPRESSED FIBRE CEMENT Bay window, with specified cladding fixed FL FLASHING in accordance with manufactures LVF FIXED ALUMINIUM LOUVRE EG1 MRS METAL ROOF SHEETING Ceiling Level specification Ceiling Level ZINC ZINC CLADDING WITH STANDING SEAM FL NGL NATURAL GROUND LINE PLY PLYWOOD WITH 10mm EXPRESSED Aluminium framed windows JOINTS fixed to manufactures SPR SPREADER 2,740 2,740 specifications Timber ballustrade, in accordance with the SPT SPITTER BCA and relevant Aus Standards Timber screen Floor Level Floor Level Ceiling Level Ceiling Level Steel post in accordance with engineers specifications Aluminium screen, in 2,740 2,740 accordance with manufacteres specifications Specified cladding fixed in accordance with manufactures specification Slab Level NGL NGL Slab Level 3 Right 1 Elevation 1:100 Specified vertical cladding Aluminium framed windows fixed to manufactures Roof sheets @ 70 pitch fixed specifications in accordance with MRS manufactures specification Ceiling Level Ceiling Level EG1 Exposed rafters to roof system Fire rated wall in accordance Specified vertical cladding with manufacturers 2,740 2,740 specifications Glass ballustrade, in Timber screen accordance with BCA and Aus Floor Level standards Floor Level Ceiling Level Ceiling Level Specified cladding Aluminium screen, in accordance with manufacteres 2,740 2,740 specifications 21 - 24 roller door Slab Level NGL NGL Slab Level 4 Front Elevation 1:100 Amendments Wind Rating Checked By: Status: PR Date: 22-01-14 PEREGIAN BEACH VILLAS A 06.12.13 Preliminary Client Approval CT Scale: 1:100 @ A3 Drawn by: CT Client Signiture Approval: C 11.12.13 Revised site plan + amendments CT Client Initials: TBC ALEX CHARLWOOD Drawing Title: D 16-01-14 Amend GFA CT Date: UNITS 6-7 , 226 DAVID LOW WAY, PEREGIAN BEACH, SUNSHINE COAST, QLD, E 22-01-14 Client request amendments CT PH: 0410 650 745 ELEVATIONS BSB No.: 1043429 NOTES: ABN: 59 980 573 352 Client: Drawing No.: PR Drawings by HINTON STEEL FRAME QLD PTY LTD. ECO REMOTE A.01.5 E ALL PLANS ARE COPYRIGHT AND MAY NOT BE REPRODUCED IN WHOLE OR AND PART WITHOUT WRITTEN PERMISION FROM HINTON STEEL FRAMES
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Large file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.