Original source · versioned page text
Attachment A -Approved Plans
The original of this document is very large (14.2 MB). Opening the original or downloading it may take a few minutes. Please be patient and don't click again. The page text is quick to read. If you are on mobile data, it is best to wait until you are on Wi-Fi.
Original PDF page 16, section 1. The text section number identifies this passage in the reader.
This document appears to be plans or drawings. Its page text below holds only the words printed on the drawings, without the drawings themselves, so it may be jumbled or hard to follow. To see the plans as drawn, choose Original above or download the file (both need you to log in).
Log in to see the plans as drawn NOTES:
unit 13, the hastings, noosa parade 1. ALL CONSTRUCTION TO BE IN ACCORDANCE WITH THE AUSTRALIAN
DOMESTIC BUILDING CODE.
2. ALL TIMBER FRAMING TO BE IN ACCORDANCE WITH AS 1684.2 2010
RESIDENTIAL TIMBER FRAMING MANUAL.
NO
3. PINE FRAMING TO BE MINIUMUM STRESS GRADE MGP 10/MGP12
4.HARDWOOD FRAMING TO BE MINIMUM STRESS GRADE F14 & MINIMUM
OS
JOINT GROUP J2.
5. TIMBER FOR TRUSSES TO BE MINIMUM JOINT GROUP JD4.
6. TRUSSES TO BE FIXED IN ACCORDANCE WITH MANUF.
A SPECIFICATIONS ALL OTHER FIXINGS TO BE IN ACCORDANCE WITH
PA
AS 1684.2 2010
7.LAMINATED BEAM SIZES BASED ON HYNEBEAM SPAN TABLES WHERE
OTHER BRANDS ARE USED, SIZES TO BE CONFIRMED WITH
RA MANUFACTURERS SPECIFICATIONS.
8. ALL DIMENSIONS TAKE PRECEDENCE OVER SCALES
DE
9. BUILDER AND TRADES ARE TO CONFIRM ALL MEASUREMENTS, DETAILS
AND SPECIFICATIONS PRIOR TO SETOUT AND ORDERING OF MATERIALS
10. ANY ERRORS ARE TO BE ADDRESSED TO THE DESIGNER AS NO
45.07 RESPONSIBILITY WILL BE TAKEN AFTER CONSTRUCTION HAS COMMENCED
0 11. ALL TRADES ARE TO CONFORM WITH THE CURRENT AUSTRALIAN
STANDARDS RELATING TO HIS OR HER OWN WORK
12. TERMITE PROTECTION TO BE PROVIDED AS PER AS 3660.1.2000
DOMESTIC SMOKE ALARMS:
1. ALL BEDROOMS AND HALLWAYS ARE TO BE INSTALLED WITH
PHOTO ELECTRIC SMOKE ALARMS IN ACCORDANCE WITH BUILDING FIRE
SAFETY LEGISLATION AMENDMENT REGULATION 2016
6600
2. SMOKE ALARMS MUST BE POSITIONED IN ACCORDANCE WITH AS
5400
1670.6 - 1997 FIRE DETECTION, WARNING, CONTROL AND INTERCOM
UNIT 14 SYSTEMS.
3. DEVICES MUST BE EITHER INTERCONNECTED OR HARD WIRED
existing timber fence (EXISTING DWELLINGS ONLY) THAT CANNOT BE
600
REMOVED FROM DEVICE
129.360
NOTE: SMOKE ALARMS TO BE INSTALLED IN ALL HALLWAYS AND BEDROOMS
TO EXISTING RESIDENCE
UNIT 13 -
NOOSA COUNCIL
APPROVED PLAN
51983.3225.08 5 APR 2017
(PROPOSED BUILD IN)
62.648
site plan
PROPOSED: CLIENT: JENIFER BASHFORD BUILDER: MICK GARDNER MANDY'S DESIGN & DRAFTING SHEET: 1 of 4 DATE: ISSUE NO:
BUILD IN GROUND+ALTERATIONS PH: 0412 104 710 PH: 0414 697 882 PH: 0403 481 474 SCALE: 1:100 MAR 2017 C
NOTE: THESE DRAWINGS TO BE READ IN CONJUNCTION NOTE: BUILDER TO CONFIRM SITING AND DIMENSIONS BEFORE CONSTRUCTION
Document Set ID: 21304948
WITH ENGINEERS DRAWINGS RESPONSIBILITY LIES THERE WITH
Version: 2, Version Date: 25/11/2020
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalVery large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.