Attachment A -Approved Plans
The original of this document is very large (14.2 MB). Opening the original or downloading it may take a few minutes. Please be patient and don't click again. The page text is quick to read. If you are on mobile data, it is best to wait until you are on Wi-Fi.
Original PDF page 17, section 1. The text section number identifies this passage in the reader.
This document appears to be plans or drawings. Its page text below holds only the words printed on the drawings, without the drawings themselves, so it may be jumbled or hard to follow. To see the plans as drawn, choose Original above or download the file (both need you to log in).
Log in to see the plans as drawn NOTES:
unit 13, the hastings, noosa parade 90 90 90
1. ALL CONSTRUCTION TO BE IN ACCORDANCE WITH THE AUSTRALIAN
DOMESTIC BUILDING CODE.
2. ALL TIMBER FRAMING TO BE IN ACCORDANCE WITH AS 1684.2 2010
elevation C
04 of 04 RESIDENTIAL TIMBER FRAMING MANUAL.
810 2280
04 of 04 3. PINE FRAMING TO BE MINIUMUM STRESS GRADE MGP 10/MGP12
01 4.HARDWOOD FRAMING TO BE MINIMUM STRESS GRADE F14 & MINIMUM
elevation B JOINT GROUP J2.
70 70 70 5. TIMBER FOR TRUSSES TO BE MINIMUM JOINT GROUP JD4.
store under 01 1630 1010 3730 6. TRUSSES TO BE FIXED IN ACCORDANCE WITH MANUF.
proposed bath/l'dry SPECIFICATIONS ALL OTHER FIXINGS TO BE IN ACCORDANCE WITH
0606AW
existing AS 1684.2 2010
90 tub 7.LAMINATED BEAM SIZES BASED ON HYNEBEAM SPAN TABLES WHERE
u/bench wms
620
+ dryer over
OTHER BRANDS ARE USED, SIZES TO BE CONFIRMED WITH
pantry
kitkitchen to be renovated MANUFACTURERS SPECIFICATIONS.
2/520
1950
2520
8. ALL DIMENSIONS TAKE PRECEDENCE OVER SCALES
shr
9. BUILDER AND TRADES ARE TO CONFIRM ALL MEASUREMENTS, DETAILS
existing cross bracing
AND SPECIFICATIONS PRIOR TO SETOUT AND ORDERING OF MATERIALS
720
(door size to 10. ANY ERRORS ARE TO BE ADDRESSED TO THE DESIGNER AS NO
RESPONSIBILITY WILL BE TAKEN AFTER CONSTRUCTION HAS COMMENCED
90
UP be confirmed)
11. ALL TRADES ARE TO CONFORM WITH THE CURRENT AUSTRALIAN
EXISTING cabinetry to be confirmed STANDARDS RELATING TO HIS OR HER OWN WORK
by owner/builder
2121OXSD
CARPORT 12. TERMITE PROTECTION TO BE PROVIDED AS PER AS 3660.1.2000
3300
0315OXSW
2600
(tiles)
DOMESTIC SMOKE ALARMS:
existing 90x90shs posts 1. ALL BEDROOMS AND HALLWAYS ARE TO BE INSTALLED WITH
90
PHOTO ELECTRIC SMOKE ALARMS IN ACCORDANCE WITH BUILDING FIRE
0315OXSW 01 SAFETY LEGISLATION AMENDMENT REGULATION 2016
2. SMOKE ALARMS MUST BE POSITIONED IN ACCORDANCE WITH AS
3290 3380 01 1670.6 - 1997 FIRE DETECTION, WARNING, CONTROL AND INTERCOM
SYSTEMS.
3. DEVICES MUST BE EITHER INTERCONNECTED OR HARD WIRED
(EXISTING DWELLINGS ONLY) THAT CANNOT BE
REMOVED FROM DEVICE
Ground Floor First Floor
elevation A
01 04 of 04
NOTE: SMOKE ALARMS TO BE INSTALLED IN ALL HALLWAYS AND BEDROOMS
TO EXISTING RESIDENCE
existing existing -
T NOOSA COUNCIL
T
APPROVED PLAN
51983.3225.08 5 APR 2017
720
720
S
S
bed
bed
01
proposed floor
elevation D
04 of 04 Upper Floor
PROPOSED: CLIENT: JENIFER BASHFORD BUILDER: MICK GARDNER MANDY'S DESIGN & DRAFTING SHEET: 3 of 4 DATE: ISSUE NO:
BUILD IN GROUND+ALTERATIONS PH: 0412 104 710 PH: 0414 697 882 PH: 0403 481 474 SCALE: 1:100 MAR 2017 C
NOTE: THESE DRAWINGS TO BE READ IN CONJUNCTION NOTE: BUILDER TO CONFIRM SITING AND DIMENSIONS BEFORE CONSTRUCTION
Document Set ID: 21304948
WITH ENGINEERS DRAWINGS RESPONSIBILITY LIES THERE WITH