Original source · versioned page text
MCU14/0106 & OPW15/0001 Appendix F - Ecological and Bushfire Management Response
Very large file: it may take a few minutes
The original of this document is very large (27.6 MB). Opening the original or downloading it may take a few minutes. Please be patient and don't click again. The page text is quick to read. If you are on mobile data, it is best to wait until you are on Wi-Fi.
Noosa Civic Expansion
Bushfire Assessment Report
Table 3-10 Vegetation Hazard Classes (VHCs) and associated Potential Fuel Loads
3.2.3 Slope Assessment
The Noosa Civic expansion site and adjacent lands are located on coastal plains with slopes generally < 5%
or approximately 2.9o.
3.2.4 Post-Development Potential Bushfire (Fire-line) Intensity
Potential Bushfire Fire-line Intensity for the Noosa Civic expansion site locality can be determined based on
the Vegetation Hazard Class (VHC), Forest Fire Danger Index (FFDI) and Slope ( ) characteristics detailed
above and using the following formulae as per Leonard et al, 2014.
The resultant potential bushfire fire-line intensity (FI) values and corresponding Potential Bushfire Intensity
Class for different sectors of the Noosa Civic expansion site that were previously defined in Section 3.1.4 and
illustrated in Figure 2 are presented in Table 3-11.
Table 3-11 SPP Potential Bushfire Intensity Classes for different parts of the Noosa Civic expansion
locality post development
Unit Description VHC Potential Potential Potential Corresponding
Class Fuel Load Bushfire Fire- Bushfire SPP 1/03 Class
(PFL) line Intensity (FI) Intensity Class4 (see Table 3-7)
t/ha kW/m
A Rec/Mu Precinct 2 30 34,081 High Medium
B Part of Noosa National
Park (North Weyba
Section) and two
parcels of Freehold 2 30 34,081 High Medium
Land situated to the
east of Walter Hay
Drive.
4
Potential Bushfire Intensity Class: Very high (potential intensity) > 40,000+kW/m; High (potential intensity) 20,000 –
40,000kW/m; Medium (potential intensity) 4,000 – 20,000kW/m; Low (Potential Intensity) < 4,000+kW/m
QIC Noosa Civic Pty Ltd Version 2 23 April 2015
J13041_Bushfire Assessment V2.docx Commercial in Confidence Page 14
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Very large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.