Bushfire Assessment Report
Unit Description VHC Potential Potential Potential Corresponding
Class Fuel Load Bushfire Fire- Bushfire SPP 1/03 Class
(PFL) line Intensity (FI) Intensity Class4 (see Table 3-7)
C Areas of open forest to
the east of Walter Hay
Drive and separated
2 30 34,081 High Medium
from Unit B by a
cleared power
transmission easement.
D Open Space Precinct 2
1-2 30-33 34,081 - 41,237 High - Very High Medium
and 4.
E Employment Precinct
1-2 30-33 34,081 - 41,237 High - Very High Medium
E7.
F Open Space Precinct
2* 30 34,081 High Medium
OS7 (Covenant J).
G Employment Precinct
2 30 34,081 High Medium
E2
H Part of Business
2* 30 34,081 High Medium
Precinct B3
I Employment Precinct
2 30 34,081 High Medium
E6.
J The proposed Noosa
16 3 341 Low Low
Civic expansion site
K The proposed Hofmann
16 3 341 Low Low
Drive extensions
L The existing Noosa
16 3 341 Low Low
Civic development
The values presented in Table 3-11 are generally consistent with the State Planning Policy’s interactive
mapping system’s bushfire hazard classifications. It is relevant to note that those areas of the site locality that
have been assigned a Very High Potential Bushfire Intensity Class all have FI scores at the lower end of the
Very High spectrum.
It is also noted that in accordance with the methodology for State-wide mapping of bushfire prone areas in
Queensland (Leonard et al, 2014), for the purpose of bushfire hazard assessments and mapping:
> small patches of a single Vegetation Hazard Class less than 1 ha are assigned the same VHC as that which
dominates the surrounding landscape (i.e. the area is assigned the same VHC as the surrounding urban
landform); and
> corridors of potentially hazardous vegetation less than 100m wide, that are isolated from other patches of
high fuel load VHCs by more than 100m, are assigned the same VHC as that which dominates the
surrounding landscape.
In this respect it is noted that the classification of Unit F as having a High Potential Bushfire Intensity Class is
conservative and does not take into account:
> the limited extent of this area which covers approximately 1.3 hectares of land;
> the narrow width of the area which ranges from 30-65 metres in width; and
> the high degree of separation that will exist post-development once the Noosa Civic expansion and
associated road network expansions have been completed.
If Unit F was assigned the same VHC as that which will dominated the post-development landscape (i.e. VHC
16 - Mixture of urban classes) then it would be classified as having a Low Potential Bushfire Intensity Class.
Similarly the classification of Unit H as having a High Potential Bushfire Intensity Class is conservative and in
practice warrants adjustment to a Low Potential Bushfire Intensity Class.
QIC Noosa Civic Pty Ltd Version 2 23 April 2015
J13041_Bushfire Assessment V2.docx Commercial in Confidence Page 15
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Very large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.