DRAWING SIZE — Al

LEGEND

4180 EXISTING SURFACE SPOT LEVELS.

—— E —— INDICATES OVERHEAD ELECTRICITY
SUPPLY LINE

INDICATES EXISTING SEWER LINE

—- w—— INDICATES WATER MAIN APPROX
ALIGNMENT, BUILDER TO CONFIRM EXACT
LOCATION PRIOR TO WORKS

—_ 7 —— INDICATES TELSTRA LINE APPROX
ALIGNMENT, BUILDER TO CONFIRM EXACT
LOCATION PRIOR TO WORKS

— sw/ExX ————_ INDICATES STORMWATER DRAIN EXISTING
AS NOTED

 

www.dialbeforeyoudig.com.au

SAS DIAL 1100

‘Wy BEFORE YOU DIG

 

  

 

 

 

 

 

 

 

  

SITE PLAN — SITE SURVEY & EXISTING SERVICES

Scale 1: 100

ALL SERVICES SHOWN ON THIS PLAN INDICATIVE
ONLY CONTRACTOR TO LOCATE ALL SERVICES
PRIOR TO COMMENCING WORKS ON SITE. ALL

SERVICES ARE TO BE PROTECTED IN
ACCORDANCE WITH THE AUTHORITY
RESPONSIBLE FOR THE SERVICE

 

 

KE

EX. SWPT
EX. SMH
EX. SCP
E.0.B.
K&C
N.S.L.
FH.
TP
EP.
KERB
RCEW
S.V
W.M

6.

r

Ke
ee
ge

 

 

27 25

EXISTING STORMWATER PIT
EXISTING SEWER MANHOLE
EXISTING SEWER CONNECTION POINT
EXISTING EDGE OF BITUMEN
EXISTING KERB & CHANNEL
NATURAL SURFACE LEVEL

FIRE HYDRANT

TELSTRA PIT

ELECTRICAL PILLAR

EXISTING KERBING

REINFORCED CONCRETE END WALL
STOP VALVE

WATER METER

CONSTRUCTION NOTES
GENERAL:

1. DO NOT SCALE FROM THIS DRAWING.
2. ALL DIMENSIONS IN MILLIMETRES
3. SETTING OUT DIMENSIONS ARE TO BE OBTAINED FROM THE

ARCHITECTURAL DRAWINGS.

4. ANY DISCREPANCIES BETWEEN THESE DRAWING AND THE
ARCHITECTURAL DRAWINGS ARE TO BE REFERRED TO THE

ENGINEER IMMEDIATELY.

5. THE BUILDER IS RESPONSIBLE FOR LOCATING ALL EXISTING
SERVICES WITHIN AND ADJACENT THE ALLOTMENT AND SHALL
ENSURE THAT ALL NEW WORKS ARE IN ACCORDANCE WITH
THE ATTACHED CRITICAL DEPTH LINE DIAGRAM.

 

 

Revision Description

 

Date

 

 

Issue:

FOR APPROVAL

 

DO NOT SCALE FROM THIS DRAWING

The design and associated details contained on this and associated
drawings are copyright and are not to be used or reproduced without
the written permission of SCG Consulting Engineers.

 

SCG HOLDINGS PTY LTD Ti

C) St6

Unit 1/11 Project Ave,
Noosa Heads

Ph (07) 5455 5604
email:[email protected]

web:www.scg-engineers.com
ABN 68 689 675 790

 

Title:

SITE SURVEY & EXISTING
SERVICES

 

Project

31 SEAVIEW TCE,
SUNSHINE BEACH

 

 

 

: D Desi
Date: JULY 24 rawn TH esign TH
0 : 5 3 4 5 Checked: Drg No. Rew
nannnt——1_r——7_7m1:100 © A1_— | RpEQ 27698
1:200 @ AS || T Harrington 01 1 1 -OW1 A .

 

 

 

 

 
Log in to download the original file

SCG 0111 - CD - 09.07.2024.pdf · 2.0 MB (small file)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.