Original source · versioned page text
Scg 0111 - Cd - 09.07.2024
Attached to the e-mail Civil Design, Architectuals, Geotech Report FW_ Lot 89 #51 Seaview Terrace_ Sunshine Beach.msg.
DRAWING SIZE — Al
LOT 89 ON RP 81810
Level Datum AHD
Level Origin PM 44264
HEIGHT DATUM
Seaview Terrace, Sunshine Beach
LEGEND
_--7-77 INDICATES PROPOSED SURFACE
43.07
4\89
= [x =
0 [—
x | 29.740
RAMP. wx.
— Sw/EX
oe RW
CONTOURS AND LEVELS TO AHD.
EXISTING SURFACE SPOT LEVELS.
INDICATES FINISHED SURFACE GRADE
INDICATES DIRECTION OF FALL
TO FINISHED SPOON DRAINS.
INDICATES DIRECTION OF RAMP UP OR
DOWN AS INDICATED
INDICATES PROPOSED FINISHED
SURFACE LEVELS
FIELD INLETS OR JUNCTION BOX PRE-CAST
CONCRETE CAST-INTO PAVEMENT. REFER SW1.1
FOR FURTHER DETAILS.
GRATED DRAIN CAST-INTO PAVEMENT.
REFER SW1.1 FOR FURTHER DETAILS
DENOTES WET TOOLED JOINT TO TERRACE
SLAB, REFER TO DRG. OW4.3 DETAILS
DENOTES SAWN CUT DANLEY JOINT
REFER TO DRG. OW4.3 DETAILS
DRIVEWAY SLAB/PAVEMENT. REFER TO
NOTES AND DETAILS ON DRG. OW4.3 FOR
THICKNESS AND REINFORCING.
LANDSCAPING, REFER LANDSCAPE
ARCHITECT FOR DETAILS.
INDICATES DIRECTION OF RAMP UP OR
DOWN AS INDICATED
INDICATES OVERHEAD ELECTRICITY
SUPPLY LINE
INDICATES EXISTING SEWER LINE
INDICATES WATER MAIN APPROX
ALIGNMENT, BUILDER TO CONFIRM EXACT
LOCATION PRIOR TO WORKS
INDICATES TELSTRA LINE APPROX
ALIGNMENT, BUILDER TO CONFIRM EXACT
LOCATION PRIOR TO WORKS
INDICATES STORMWATER DRAIN EXISTING
AS NOTED
INDICATES POSITION OF RETAINING WALL
TO STRUCTURAL ENGINEERS DETAIL.
>
www.dialbeforeyoudig.com.au
SAY DIAL 1100
BEFORE YOU DIG
KEY
EX. SWPT EXISTING STORMWATER PIT
EX. SMH — EXISTING SEWER MANHOLE
EX. SCP EXISTING SEWER CONNECTION POINT
FOR STORMWATER PIT
DETAILS. REFER DRG
O111-SW1.1. TYPICAL
5
2.3
2b 235
2.388
nO *<
ao! 57
ie?
e
717 KOre
4x0
RESIDENTIAL
DEVELOPMENT
FFL: 23.750
24.1
SITE PLAN — DRIVEWAY & CROSSOVER PLAN
Scale 1: 100
ALL SERVICES SHOWN ON THIS PLAN INDICATIVE
ONLY CONTRACTOR TO LOCATE ALL SERVICES
PRIOR TO COMMENCING WORKS ON SITE. ALL
SERVICES ARE TO BE PROTECTED IN
ACCORDANCE WITH THE AUTHORITY
RESPONSIBLE FOR THE SERVICE
CONTRACTOR TO TOPSOIL AND TURF ANY
DISTURBED OR DAMAGED AREAS OF THE ROAD
RESERVE ADJACENT THE CONSTRUCTION SITE
ALL LINE MARKING TO BE IN ACCORDANCE
WITH THE QUEENSLAND MANUAL OF UNIFORM
TRAFFIC CONTROL DEVICES & A.S 2890.1
PARKING FACILITIES PART 1: OFF-STREET CAR
PARKING
CONTRACTOR TO REPAIR/REINSTATE ANY
DAMAGED AREAS OF EXISTING FOOTPATHS,
KERB & CHANNELS TO COUNCIL STANDARDS
BUILDING OVER 'NG OVER
(SWP)
2g >>
sl?
2 <4
“a ave 7
ZO Ky
o> a
4d ¥
<a
DRIVEWAY CROSSOVER GENERALLY IN
ACCORDANCE WITH IPWEA STD DRG RS-049 &
RS-050 AND COUNCIL REQUIREMENTS. LEVELS
AS NOTED, REFER DRG OW4.2 FOR DETAILS.
DEMOLISH & REMOVE EXISTING
DRIVEWAY CROSSOVER AND
RE-CONSTRUCT NEW TYPE B1 BARRIER
KERB & CHANNEL AS PER NOOSA
COUNCIL STD DETAIL IPWEA RS—080.
MAINTAIN EXISTING SURFACE GRADES
AND ENSURE SMOOTH TRANSITIONS.
MAXIMUM CROSS-FALL OF 1 in 40 ON ALL
FOOT-PATHS AND INTERNAL PEDESTRIAN
PATHS AND RAMPS
CONTRACTOR TO REPAIR ADJACENT THE
CONSTRUCTION SITE KERB, FOOTPATH OR
ROAD RESERVE IF ANY DAMAGE IS SUSTAINED
DURING CONSTRUCTION. GRASSED AREAS ARE
TO BE RE TOP SOILED AND TURFED.
NEW KERB & CHANNEL TO BE IN ACCORDANCE
WITH IPWEA STANDARD Drg. SEQ-RS-080 &
COUNCIL STANDARD DETAILS
E.0.B. EXISTING EDGE OF BITUMEN
K&C EXISTING KERB & CHANNEL
N.S.L. NATURAL SURFACE LEVEL
FH. FIRE HYDRANT
TP TELSTRA PIT
EP. ELECTRICAL PILLAR
KERB
RCEW
S.V
W.M
<2. 25HE7 25
0
1:200 @ A3
1
EXISTING KERBING
REINFORCED CONCRETE END WALL
STOP VALVE
WATER METER
2 3 4 5
CONSTRUCTION NOTES
GENERAL:
1. DO NOT SCALE FROM THIS DRAWING,
2. ALL DIMENSIONS IN. MILLIMETRES
3. SETTING OUT DIMENSIONS ARE TO BE OBTAINED FROM THE
ARCHITECTURAL DRAWINGS.
4, ANY DISCREPANCIES BETWEEN THESE DRAWING AND THE
ARCHITECTURAL DRAWINGS ARE TO BE REFERRED TO THE
ENGINEER IMMEDIATELY.
5. THE BUILDER IS RESPONSIBLE FOR LOCATING ALL EXISTING
SERVICES WITHIN AND ADJACENT THE ALLOTMENT AND SHALL
ENSURE THAT ALL NEW WORKS ARE IN ACCORDANCE. WITH
THE ATTACHED CRITICAL DEPTH LINE DIAGRAM.
FOOTPATHS AND DRIVEWAYS:
1. EXISTING FOOTPATHS TO BE SAW CUT PRIOR TO REMOVAL
2. MINIMUM CONCRETE THICKNESSES:
PAVEMENT (VEHICLES): 125mm U.N.O.
FOOTPATHS: 100mm _U.N.O.
3. CONCRETE IN ACCORDANCE WITH AS360 AND AS1379
AND MINIMUM STRENGTHS AS FOLLOWS:
PAVEMENT (VEHICLES): 32 MPa
FOOTPATHS: 25 MPa
4. CONCRETE SURFACE TOLERANCE +5.0mm OVER 3.0m
5. REINFORCEMENT FABRIC TO AS 1304, PLACED CENTRAL
SLAB DEPTH.
6. MAX. 1 in 40 CROSSFALL (ACCROSS) ON FOOTPATHS.
7. EXPANSION JOINTS AS NOTED (T.J.) ON PLANS 10 BE
10mm WIDE WET TOOLED WITH EVERY 2ND MESH WIRE CUT
ALONG JOINT. REFER DETAIL.
8. ONE ACCESS POINT PERMITTED FOR EACH ALLOTMENT.
9. FOR CURVED DRIVEWAYS, MAXIMUM GRADES APPLY TO
INSIDE EDGE OF CURVE
10. ALL EXISTING SERVICES TO BE LOCATED AND PROTECTED
AS REQUIRED PRIOR TO WORK COMMENCING
A COUNCIL RFI 10.07.24
Revision Description Date
Issue:
FOR APPROVAL
DO NOT SCALE FROM THIS DRAWING
The design and associated details contained on this and associated
drawings are copyright and are not to be used or reproduced without
the written permission of SCG Consulting Engineers.
email:[email protected]
web:www.scg-engineers.com
ABN 68 689 675 790
_ Unit 1/11 Project Ave,
P Noosa Heads
Ph (07) 5455 5604
SCG HOLDINGS PTY LTD Ti
Title:
DRIVEWAY & ACCESS PLAN
Project
31 SEAVIEW TCE,
SUNSHINE BEACH
Date: Drawn Design
JULY 24 TH
TH
Checked: Drg No.
jmeze O11 -Ow2.1) A